Pulveriser Mill Outlet Temperature and Air to Coal Ratio

Mill outlet temperature of a coal pulveriser from the primary air flow and temperature, coal feed and moisture, by a heat balance, with the air to coal ratio.

Thermal power plantProcess steam and utilitiesChemical and fertiliserPulp and paperASME PTC 4 (fired steam generators)IAPWS-IF97 (water and steam)BoilerBurner and furnace

Inputs

Examples: Bituminous 30 t/h, 15 % moisture, 60 t/h air at 280 °CIndian coal 40 t/h, 12 %, 72 t/h air at 260 °CLignite 25 t/h, 35 %, 75 t/h air at 320 °C

From the coal analysis or the mill maker.
About 0.01 for temperate air, up to 0.02 to 0.03 for humid tropical air; from the psychrometric chart at the air intake.

Results

The mill outlet temperature limit depends on the coal's volatile matter (fire and explosion risk); check the mill maker's limit.

Mill outlet temperature79.652°C
Primary air (dry) to coal ratio3.0000kg/kg
Water evaporated in the mill6.9444t/h
Heat taken by drying and heating the coal5,263.3kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bituminous 30 t/h, 15 % moisture, 60 t/h air at 280 °C. The inputs, in the units selected above:

InputValue
Raw coal feed to the mill30.000 t/h
Total moisture of the raw coal15.000 %
Moisture left in the pulverised coal2.0000 %
Raw coal temperature30.000 °C
Specific heat of the dry coal1.2500 kJ/(kg·K)
Primary air flow, dry60.000 t/h
Primary air temperature at the mill inlet280.00 °C
Primary air humidity, kg water per kg dry air0.013000 kg/kg
Mill grinding power (enters as heat)150.00 kW
Heat lost from the mill casing and ducts50.000 kW

Applying the formula below gives:

ResultValue
Mill outlet temperature91.381 °C
Primary air (dry) to coal ratio2.0000 kg/kg
Water evaporated in the mill3.9796 t/h
Heat taken by drying and heating the coal3,394.7 kW

Open this example in the calculator and change any input.

Formula

\(w = \frac{M_{in} - M_{out}}{1 - M_{out}}, \quad \dot m_w = \dot m_c w\)

\(Q_c = \dot m_w [h_v(T_o) - h_f(T_c)] + \dot m_c (1 - M_{in}) c_c (T_o - T_c) + \dot m_c (M_{in} - w) [h_f(T_o) - h_f(T_c)]\)

\(h_a(T) = h_{da}(T) + x_a h_{v,ig}(T), \quad \dot m_a [h_a(T_{in}) - h_a(T_o)] + P_m - Q_l = Q_c\)

Variables

Symbol Meaning SI unit
\(\dot m_c\) raw coal feed kg/s
\(M_{in}\) total moisture of the raw coal -
\(M_{out}\) moisture left in the pulverised coal -
\(T_c\) raw coal temperature K
\(c_c\) specific heat of the dry coal J/(kg·K)
\(P_m\) mill grinding power, entering as heat W
\(Q_l\) mill casing and duct heat loss W
\(\dot m_w\) water evaporated kg/s
\(Q_c\) heat taken by the coal side W
\(\dot m_a\) primary air flow, dry air kg/s
\(T_{in}\) primary air temperature at the mill inlet K
\(T_o\) mill outlet temperature K
\(r\) primary air (dry) to coal ratio kg/kg
\(h_v\) water vapour enthalpy at T_o and 1 psia J/kg
\(h_f\) liquid water enthalpy J/kg
\(h_a\) humid air enthalpy per kg dry air: dry air plus x_a kg of ideal-gas water vapour J/kg
\(x_a\) primary air humidity, kg water vapour per kg dry air kg/kg
\(h_{da}\) dry air enthalpy J/kg
\(h_{v,ig}\) ideal-gas water vapour enthalpy J/kg
\(w\) water evaporated per kg raw coal kg/kg

Method and standards

A heat balance on the mill: the hot primary air gives up heat between the mill inlet and outlet temperatures; with the grinding power (which ends as heat) it evaporates the surface moisture and warms the coal and the water left in it. The evaporated water leaves as vapour (IAPWS-IF97 at 1 psia, as ASME PTC 4 treats flue gas moisture); the primary air is humid: per kg of dry air it carries x_a kg of water vapour, and its enthalpy is dry air plus that vapour as an ideal gas from NIST Shomate data, the basis ASME PTC 4 uses for moisture in air. The outlet temperature is found by solving the balance.

Where it is used

  • Predicting mill outlet temperature after a change in coal moisture.
  • Checking the air heater outlet needed for a target outlet temperature.
  • Commissioning and tuning primary air control.

Common mistakes

  • Using wet-basis and dry-basis moisture interchangeably.
  • Forgetting the grinding heat.
  • Treating the air to coal ratio as fixed across the load range.

Assumptions and limits

  • Steady state; the primary air flow is dry air, and the humidity entered is carried as vapour.
  • If the heat supplied exceeds the coal's need even at the inlet air temperature, the outlet is shown at that temperature with a note.
  • Surface moisture removed is total moisture less the moisture left in the pulverised coal.
  • No allowance for seal air or leakage.

References

  • Mill heat balance
  • IAPWS-IF97
  • ASME PTC 4 (vapour at 1 psia)

Questions and answers

What outlet temperature will a mill reach?

In the example, 30 t/h of 15 % moisture coal with 60 t/h of air at 280 °C reaches about 91 °C at the outlet (primary air humidity 0.013 kg/kg).

What air to coal ratio do mills run at?

Roughly 1.5 to 2.5 kg air per kg coal for vertical spindle mills; the mill maker sets the curve against load.

Why limit the outlet temperature?

Hot, high-volatile coal dust can ignite in the mill and pipes; the limit falls as volatile matter rises.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators