Worked example
Example: 30 MW cogen, 250 TCH. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Power generated | 30.000 MW |
| Cogeneration plant auxiliaries (share of generation) | 8.0000 % |
| Sugar mill power use | 7.0000 MW |
| Crushing rate | 250.00 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power exported | 20.600 MW |
| Exported per tonne cane | 82.400 kWh/t |
| Generated per tonne cane | 120.00 kWh/t |
Open this example in the calculator and change any input.
Formula
\(P_x = P_g (1 - k_a) - P_m, \quad e_x = \frac{P_x}{C}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_g\) | Power generated | W |
| \(k_a\) | Cogeneration plant auxiliaries (share of generation) | - |
| \(P_m\) | Sugar mill power use | W |
| \(C\) | Crushing rate | kg/s |
| \(P_x\) | Power exported | W |
| \(e_x\) | Exported per tonne cane | J/kg |
| \(e_g\) | Generated per tonne cane | J/kg |
Method and standards
Energy balance.
Where it is used
- Cogeneration feasibility and tariff studies.
Common mistakes
- Mixing gross and net generation.
Assumptions and limits
- Steady operation.
- Off-season (crushing rate 0) gives the export power only; the per-tonne figures need cane.
References
- Energy balance; kWh/t = kW ÷ t/h
Questions and answers
What decides kWh per tonne cane?
Boiler pressure and temperature, steam % cane and the turbine configuration.
Season and off-season?
Run the calculator for each with its own generation and mill use.
Auxiliaries?
Boiler fans, feed pumps and cooling tower: take them from the plant meter.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.