Worked example
Example: 6 lakh t season. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cane crushed in the season | 600,000 t |
| Bagasse % cane | 29.000 % |
| Boiler steam % cane | 50.000 % |
| Steam-to-bagasse ratio | 2.2000 kg/kg |
| Bagasse kept for the off-season | 30,000 t |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bagasse produced | 174,000 t |
| Bagasse burnt in season | 136,364 t |
| Surplus (+) or deficit (−) | 7,636.4 t |
| Surplus % of bagasse produced | 4.3887 % |
Open this example in the calculator and change any input.
Formula
\(B_p = C_s B, \quad B_b = \frac{C_s s_b}{r}, \quad B_x = B_p - B_b - B_{off}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_s\) | Cane crushed in the season | kg |
| \(B\) | Bagasse % cane | - |
| \(s_b\) | Boiler steam % cane | - |
| \(r\) | Steam-to-bagasse ratio | kg/kg |
| \(B_{off}\) | Bagasse kept for the off-season | kg |
| \(B_p\) | Bagasse produced | kg |
| \(B_b\) | Bagasse burnt in season | kg |
| \(B_x\) | Surplus (+) or deficit (−) | kg |
| \(B_x/B_p\) | Surplus % of bagasse produced | - |
Method and standards
Mass balance.
Where it is used
- Season fuel planning.
- Cogeneration feasibility.
Common mistakes
- Steam % cane for process used instead of boiler steam.
Assumptions and limits
- Season totals.
- Bagasse % cane and the steam-to-bagasse ratio must be on the same moisture basis (bagasse as fired, normally about 50 % moisture).
- Storage losses of the off-season bagasse (heating, decay) are not included.
References
- Mass balance of bagasse over a season
Questions and answers
How to raise the surplus?
Lower steam % cane, raise boiler efficiency, dry the bagasse.
What steam-to-bagasse ratio?
About 2.0–2.4 for 50 % moisture bagasse in modern boilers.
Surplus use?
Off-season power, sale, or a distillery boiler.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.