FireCADCalc

Bagasse or Biomass Feeder Capacity and Number of Feeders

Throughput of a drum, belt or screw feeder from its width, fuel bed height, speed and fuel bulk density, and the feeders needed for a firing rate with spares.

Sugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: Drum feeders on bagasseHusk screw feederDrum feeders at 80 % fill

Real feeders deliver less than the full-bed volume: enter a factor from weighing, or a design margin.

Results

Bulk density of bagasse varies with moisture and packing: calibrate the feeder by weighing.

One feeder1.1880t/h
Feeders in service4.0000
Feeders installed5.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Drum feeders on bagasse. The inputs, in the units selected above:

InputValue
Feeder width0.60000 m
Fuel bed height0.25000 m
Feeder surface speed6.0000 m/min
Fuel bulk density140.00 kg/m³
Fuel firing rate30.000 t/h
Spare feeders1.0000 -
Fill and slip factor (1 = full bed, no slip)100.00 %

Applying the formula below gives:

ResultValue
One feeder7.5600 t/h
Feeders in service4.0000
Feeders installed5.0000

Open this example in the calculator and change any input.

Formula

\(\dot m_1 = \phi\,\rho_b W H v, \quad N = \lceil \dot m_f / \dot m_1 \rceil\)

Variables

Symbol Meaning SI unit
\(W\) Feeder width m
\(H\) Fuel bed height m
\(v\) Feeder surface speed m/s
\(\rho_b\) Fuel bulk density kg/m³
\(\dot m_f\) Fuel firing rate kg/s
\(n_s\) Spare feeders -
\(\phi\) Fill and slip factor -
\(\dot m_1\) One feeder kg/s
\(N\) Feeders in service -
\(N_t\) Feeders installed -

Method and standards

Volumetric feed.

Where it is used

  • Feeder selection.
  • Fuel system debottlenecking.

Common mistakes

  • Loose and compacted density mixed.

Assumptions and limits

  • The fill and slip factor (default 1, full bed) and the spares carry any design margin; with 1 the feeders in service run at 100 % of their volumetric rating.

References

  • Volumetric throughput ṁ = ρ W H v

Questions and answers

Why several feeders?

They spread fuel across the grate and allow one to stop without losing the boiler.

Speed control?

VFDs on feeders follow the steam pressure.

Why does bulk density matter?

A feeder moves volume; mass depends on how the bagasse packs.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.