Bagasse Combustion: Air, Flue Gas and CO₂ (Hugot)

Air and flue gas per kg of bagasse, gas composition and dry CO₂ for an excess-air factor (Hugot 41.27–41.39), and excess air from measured CO₂.

Sugar mill and cogenerationBoilerFan and blower

Inputs

Examples: Hugot example: w 0.48, m 1.5Drier bagasse, m 1.3

Results

Hugot's bagasse: C 47, H 6.5, O 44, ash 2.5 % of dry matter; 5.76 kg (4.45 Nm³) of air per kg dry bagasse. Best CO₂ 12–16 %, 25–60 % excess air.

Air per kg bagasse4.1184kg/kg
Air per kg bagasse, Nm³/kg (0 °C, 1 atm)3.1818
Wet flue gas per kg bagasse (ash included, as Hugot)5.1184kg/kg
Wet flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm)4.1112
Dry flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm)3.1510
N₂ by mass62.050%
O₂ by mass4.2990%
H₂O by mass15.119%
CO₂ by mass18.532%
Dry CO₂ by volume15.186%
Air factor from the measured CO₂1.3193

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: w 0.48, m 1.5. The inputs, in the units selected above:

InputValue
Bagasse moisture48.000 %
Air factor (actual / theoretical air)1.5000 -
Measured dry CO₂ (for the reverse check)13.000 %

Applying the formula below gives:

ResultValue
Air per kg bagasse4.4928 kg/kg
Air per kg bagasse, Nm³/kg (0 °C, 1 atm)3.4710
Wet flue gas per kg bagasse (ash included, as Hugot)5.4928 kg/kg
Wet flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm)4.4176
Dry flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm)3.4419
N₂ by mass63.057 %
O₂ by mass6.3104 %
H₂O by mass14.311 %
CO₂ by mass16.322 %
Dry CO₂ by volume13.144 %
Air factor from the measured CO₂1.5203

Open this example in the calculator and change any input.

Formula

\(P_a = 5.76(1 - w)m, \quad P_g = P_a + 1, \quad V_{gs} = 4.45(1 - w)m - 0.056(1 - w), \quad \gamma = \frac{0.87(1 - w)}{V_{gs}}, \quad m_\gamma = \frac{0.196}{\gamma} + 0.0126\)

Variables

Symbol Meaning SI unit
\(w\) Bagasse moisture -
\(m\) Air factor (actual / theoretical air) -
\(\gamma\) Measured dry CO₂ (for the reverse check) -
\(P_a\) Air per kg bagasse kg/kg
\(V_a\) Air per kg bagasse, Nm³/kg -
\(P_g\) Wet flue gas per kg bagasse (ash included, as Hugot) kg/kg
\(V_g\) Wet flue gas per kg bagasse, Nm³/kg -
\(V_{gs}\) Dry flue gas per kg bagasse, Nm³/kg -
\(x_{N_2}\) N₂ by mass -
\(x_{O_2}\) O₂ by mass -
\(x_{H_2O}\) H₂O by mass -
\(x_{CO_2}\) CO₂ by mass -
\(m_\gamma\) Air factor from the measured CO₂ -

Method and standards

Hugot's combustion balance for bagasse of standard composition.

Where it is used

  • Fan sizing for bagasse boilers.
  • Setting excess air from CO₂ readings.

Common mistakes

  • Using dry-basis air with wet bagasse.
  • Measuring CO₂ on wet gas.

Assumptions and limits

  • Hugot's average composition; complete combustion.
  • P_g = P_a + 1 is Hugot's form and counts the ash with the gas; the mass fractions are from the gas components only, so they differ slightly.
  • Volumes in Nm³ at 0 °C and 1 atm.
  • A note appears when the air factor from the measured CO₂ differs from the one entered by more than 10 %.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 41
  • combustion of bagasse
  • eqns 41.13 and 41.27–41.40
  • pp. 918–923

Questions and answers

Why per kg of wet bagasse?

Boiler fuel is weighed wet; Hugot writes everything per kg as fired, with (1 − w) for the dry part.

Why is CO₂ limited to about 20 %?

Bagasse's hydrogen and oxygen give a maximum dry CO₂ of about 19.8 % with theoretical air.

Why not use the minimum air?

Moist bagasse burns incompletely without excess air; too much air carries heat up the stack.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.