Worked example
Example: Hugot example: w 0.48, m 1.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bagasse moisture | 48.000 % |
| Air factor (actual / theoretical air) | 1.5000 - |
| Measured dry CO₂ (for the reverse check) | 13.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air per kg bagasse | 4.4928 kg/kg |
| Air per kg bagasse, Nm³/kg (0 °C, 1 atm) | 3.4710 |
| Wet flue gas per kg bagasse (ash included, as Hugot) | 5.4928 kg/kg |
| Wet flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm) | 4.4176 |
| Dry flue gas per kg bagasse, Nm³/kg (0 °C, 1 atm) | 3.4419 |
| N₂ by mass | 63.057 % |
| O₂ by mass | 6.3104 % |
| H₂O by mass | 14.311 % |
| CO₂ by mass | 16.322 % |
| Dry CO₂ by volume | 13.144 % |
| Air factor from the measured CO₂ | 1.5203 |
Open this example in the calculator and change any input.
Formula
\(P_a = 5.76(1 - w)m, \quad P_g = P_a + 1, \quad V_{gs} = 4.45(1 - w)m - 0.056(1 - w), \quad \gamma = \frac{0.87(1 - w)}{V_{gs}}, \quad m_\gamma = \frac{0.196}{\gamma} + 0.0126\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Bagasse moisture | - |
| \(m\) | Air factor (actual / theoretical air) | - |
| \(\gamma\) | Measured dry CO₂ (for the reverse check) | - |
| \(P_a\) | Air per kg bagasse | kg/kg |
| \(V_a\) | Air per kg bagasse, Nm³/kg | - |
| \(P_g\) | Wet flue gas per kg bagasse (ash included, as Hugot) | kg/kg |
| \(V_g\) | Wet flue gas per kg bagasse, Nm³/kg | - |
| \(V_{gs}\) | Dry flue gas per kg bagasse, Nm³/kg | - |
| \(x_{N_2}\) | N₂ by mass | - |
| \(x_{O_2}\) | O₂ by mass | - |
| \(x_{H_2O}\) | H₂O by mass | - |
| \(x_{CO_2}\) | CO₂ by mass | - |
| \(m_\gamma\) | Air factor from the measured CO₂ | - |
Method and standards
Hugot's combustion balance for bagasse of standard composition.
Where it is used
- Fan sizing for bagasse boilers.
- Setting excess air from CO₂ readings.
Common mistakes
- Using dry-basis air with wet bagasse.
- Measuring CO₂ on wet gas.
Assumptions and limits
- Hugot's average composition; complete combustion.
- P_g = P_a + 1 is Hugot's form and counts the ash with the gas; the mass fractions are from the gas components only, so they differ slightly.
- Volumes in Nm³ at 0 °C and 1 atm.
- A note appears when the air factor from the measured CO₂ differs from the one entered by more than 10 %.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- combustion of bagasse
- eqns 41.13 and 41.27–41.40
- pp. 918–923
Questions and answers
Why per kg of wet bagasse?
Boiler fuel is weighed wet; Hugot writes everything per kg as fired, with (1 − w) for the dry part.
Why is CO₂ limited to about 20 %?
Bagasse's hydrogen and oxygen give a maximum dry CO₂ of about 19.8 % with theoretical air.
Why not use the minimum air?
Moist bagasse burns incompletely without excess air; too much air carries heat up the stack.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.