Worked example
Example: Hugot example: 28 kg/cm2 g 380 °C, feed 90. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bagasse moisture | 48.000 % |
| Sugar in bagasse | 2.0000 % |
| Air factor | 1.4000 - |
| Flue gas temperature | 200.00 °C |
| Product of combustion, radiation and heat-loss factors | 91.267 % |
| Steam pressure (absolute) | 28.439 bar |
| Steam temperature | 380.00 °C |
| Feed water temperature | 90.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Net calorific value | 7,946.5 kJ/kg |
| Gross calorific value 4600 − 12s − 46w | 9,914.3 kJ/kg |
| Flue gas loss | 1,215.5 kJ/kg |
| Heat to steam per kg bagasse | 6,143.2 kJ/kg |
| Efficiency on GCV | 61.963 % |
| Heat per kg of steam | 2,809.6 kJ/kg |
| Steam per kg bagasse | 2.1865 |
Open this example in the calculator and change any input.
Formula
\(q = [(1 - w)(1.4m - 0.13) + 0.5]t, \quad M_v = (4250 - 4850w - 1200s - q)\alpha\beta\eta\ [\mathrm{kcal/kg}]\)
\(\rho = \frac{M_v}{4600 - 12s - 46w}, \quad \frac{S}{B} = \frac{M_v}{h_s - h_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Bagasse moisture | - |
| \(s\) | Sugar in bagasse | - |
| \(m\) | Air factor | - |
| \(t\) | Flue gas temperature | K |
| \(\alpha\beta\eta\) | Product of combustion, radiation and heat-loss factors | - |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(T_s\) | Steam temperature | K |
| \(t_f\) | Feed water temperature | K |
| \(N\) | Net calorific value | J/kg |
| \(G\) | Gross calorific value 4600 − 12s − 46w | J/kg |
| \(q\) | Flue gas loss | J/kg |
| \(M_v\) | Heat to steam per kg bagasse | J/kg |
| \(\rho\) | Efficiency on GCV | - |
| \(\Delta h\) | Heat per kg of steam | J/kg |
| \(S/B\) | Steam per kg bagasse | - |
Method and standards
Hugot's indirect method with IF97 steam enthalpies (s, w in % in the GCV form).
Where it is used
- Bagasse boiler performance checks.
- Steam balance planning.
Common mistakes
- Using GCV-based efficiency with NCV heat.
- Feed temperature after the economiser vs before.
Assumptions and limits
- Hugot's average bagasse composition; his GCV and NCV correlations ignore ash and suit normal cane bagasse (moisture about 40–55 %). The flue gas loss is referred to 0 °C as in Hugot.
- M_v uses the NCV, while the efficiency divides it by the GCV, as Hugot defines it.
- The steam must be superheated (or dry) and the feed water liquid; otherwise the page stops.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- eqns 41.20
- 41.25 and 41.48–41.51 and Table 41.22
- pp. 913–916 and 932–935
- Steam and feed enthalpies from IAPWS-IF97
Questions and answers
Why is efficiency on GCV only 50–65 %?
The water in bagasse and from its hydrogen leaves as vapour, so the latent heat in the GCV is never recovered.
What does 1.4m − 0.13 mean?
Hugot's flue gas heat per °C per kg of dry bagasse at air factor m.
Typical steam per kg?
Hugot: 2–2.7, often about 2.25 kg of steam per kg of bagasse.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.