FireCADCalc

Spent Wash per Litre of Alcohol

Spent wash (vinasse) per litre of alcohol and per day from the wash strength, the live steam injected in the analyser column and the plant capacity.

Distillery and ethanol

Inputs

Examples: 9 % wash, live steam12 % wash, reboiler

0 for reboiler-heated (indirect) columns.

Results

An estimate by volume balance; plants report 8–15 L per litre for molasses: measure yours.

Spent wash per litre of AA12.034
Spent wash per day1,203.4m³/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 9 % wash, live steam. The inputs, in the units selected above:

InputValue
Wash strength9.0000 %
Live steam injected per litre of AA2.0000 kg/L
Plant capacity (absolute alcohol)100.00 kL/d
Spent wash density1,040.0 kg/m³

Applying the formula below gives:

ResultValue
Spent wash per litre of AA12.034
Spent wash per day1,203.4 m³/d

Open this example in the calculator and change any input.

Formula

\(v_{sw} = \frac{1}{s_v} - 1 + \frac{s_s}{\rho_w}\)

Variables

Symbol Meaning SI unit
\(s_v\) Wash strength -
\(s_s\) Live steam injected per litre of AA kg/m³
\(\dot V_e\) Plant capacity (absolute alcohol) m³/s
\(\rho_w\) Spent wash density kg/m³
\(v_{sw}\) Spent wash per litre of AA -
\(\dot V_{sw}\) Spent wash per day m³/s

Method and standards

Volume balance.

Where it is used

  • ZLD planning.
  • Pollution control consent applications.

Common mistakes

  • Bulk litres used.

Assumptions and limits

  • Volumes additive.
  • Only the absolute alcohol is taken out of the wash: water leaving with the overhead (low wines) and the lees stream are not separated, and condensed steam is counted at the spent wash density. The result is an estimate; measure the flow.

References

  • Volume balance: wash per litre of AA = 1/s_v; less the alcohol; plus condensed live steam

Questions and answers

How to cut spent wash?

Higher wash strength, reboilers instead of live steam, and recycle of spent wash to dilution.

Why does live steam add spent wash?

Injected steam condenses into the bottoms.

Is the estimate exact?

No: densities, contraction and recycle shift it; measure the flow.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.