FireCADCalc

Sugar Crystal Size: Mean Aperture (MA) and CV

Mean aperture and coefficient of variation of a sugar's crystal size from the 16, 50 and 84 % points of its cumulative sieve curve (Powers).

Sugar mill and cogeneration

Inputs

Examples: Plantation whiteFine sugar

Results

Read the three sizes from the cumulative curve on probability paper or by interpolation. Either a passing or a retained curve may be used: CV uses the spread between the 16 % and 84 % sizes.

Mean aperture0.60000mm
Coefficient of variation30.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Plantation white. The inputs, in the units selected above:

InputValue
Size at the 16 % point of the cumulative curve0.42000 mm
Size at 50 % cumulative (median)0.60000 mm
Size at the 84 % point of the cumulative curve0.78000 mm

Applying the formula below gives:

ResultValue
Mean aperture0.60000 mm
Coefficient of variation30.000 %

Open this example in the calculator and change any input.

Formula

\(MA = d_{50}, \quad CV = \frac{|d_{84} - d_{16}|}{2\,d_{50}}\)

Variables

Symbol Meaning SI unit
\(d_{16}\) Size at the 16 % point of the cumulative curve m
\(d_{50}\) Size at 50 % cumulative (median) m
\(d_{84}\) Size at the 84 % point of the cumulative curve m
\(MA\) Mean aperture m
\(CV\) Coefficient of variation -

Method and standards

Powers.

Where it is used

  • Pan control.
  • Sugar grading.

Common mistakes

  • Sizes read from a passing curve with the points swapped.

Assumptions and limits

  • Near-normal distribution; a clearly skewed curve (16 % and 84 % sizes far from symmetric about the median) is flagged.
  • On a retained curve the 16 % size is the coarser one, on a passing curve the finer; either order is accepted and CV uses the spread.

References

  • Powers (1948) MA/CV for a normal size distribution: CV = 100 (d84 − d16)/(2 d50)

Questions and answers

What CV is good?

Lower is more uniform; refined sugars aim for a low CV for packing and appearance.

Why 16 and 84 %?

They lie one standard deviation either side of the median for a normal distribution.

Why does uniformity matter for curing?

Fines block the screen and hold molasses.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.