FireCADCalc

Intermediate Carrier Speed, Layer and Power (Hugot)

Speed, bagasse layer thickness and motor of an intermediate carrier between mills from the mill speed and the fibre rate, by Hugot eqns 8.4 and 8.5.

Sugar mill and cogenerationElectric motor

Inputs

Examples: Rake carrierApron carrier

Hugot: rake carriers 1.5–3; slat (apron) carriers about 1.1.
Hugot: about 95 kg of fibre per m³ of layer on a rake carrier. This is fibre only, not the bulk density of the wet bagasse.

Results

Hugot's rule of thumb: an intermediate carrier takes about 5 % of the power of the mill it feeds (not computed here).

Carrier speed30.000m/min
Layer thickness105.99mm
Carrier motor (Hugot 0.075 kW per t cane/h)18.750kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Rake carrier. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Fibre % cane14.500 %
Peripheral speed of the mill fed15.000 m/min
Carrier speed / mill speed2.0000 -
Carrier width2.0000 m
Fibre (not bagasse) per cubic metre of bagasse layer95.000 kg/m³

Applying the formula below gives:

ResultValue
Carrier speed30.000 m/min
Layer thickness105.99 mm
Carrier motor (Hugot 0.075 kW per t cane/h)18.750 kW

Open this example in the calculator and change any input.

Formula

\(V' = k V, \quad h = \frac{A f}{V' L\,\rho_f}, \quad T = 0.075\,A \;[\mathrm{kW},\ A\ \mathrm{in\ t/h}]\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(V\) Peripheral speed of the mill fed m/s
\(V'/V\) Carrier speed / mill speed -
\(L\) Carrier width m
\(\rho_f\) Fibre per cubic metre of bagasse layer kg/m³
\(V'\) Carrier speed m/s
\(h\) Layer thickness m
\(T\) Carrier motor (Hugot 0.075 kW per t cane/h) W

Method and standards

Hugot's continuity of fibre and his power rule.

Where it is used

  • Carrier design between mills.
  • Checking layer thickness after a crush increase.

Common mistakes

  • Using the cane rate instead of the fibre rate for the layer.
  • Taking the roller rpm as the peripheral speed.

Assumptions and limits

  • Uniform layer; loose bagasse.
  • ρ_f is fibre per m³ of layer, not the bulk density of the wet bagasse; entering a bagasse bulk density gives too thin a layer.
  • In the motor rule A is in t/h and T in kW; the page converts from SI.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 8
  • eqns 8.4–8.5 and p. 77

Questions and answers

Why run faster than the mill?

A faster carrier spreads a thinner layer that feeds evenly; rake carriers run 1.5–3 times the mill speed.

Where does 95 kg/m³ come from?

Hugot's figure for the fibre content of the loose bagasse layer on a rake carrier.

Motor size?

About 0.075 kW per t cane/h for each intermediate carrier.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.