Worked example
Example: Knives as shredder, motor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Fibre % cane | 14.500 % |
| Installed power per tonne of fibre per hour (kW/(t fibre/h), not per t cane) | 20.000 kWh/t |
| Mean absorbed power / installed power | 60.000 % |
| Drive | Electric motor |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fibre rate | 36.250 t/h |
| Installed power (electric motor rating) | 725.00 kW |
| Mean absorbed power | 435.00 kW |
| Drive rating (motor: P_i; turbine: 1.33 P_i) | 725.00 kW |
| Installed power per tonne cane per hour | 2.9000 kWh/t |
Open this example in the calculator and change any input.
Formula
\(P_i = e\,A f, \quad P_a = \varphi P_i, \quad P_d = P_i\ \text{(motor)},\ 1.33\,P_i\ \text{(turbine)}, \quad \frac{P_i}{A}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre % cane | - |
| \(e\) | Installed power per tonne of fibre per hour (kW/(t fibre/h), not per t cane) | J/kg |
| \(\varphi\) | Mean absorbed power / installed power | - |
| \(\text{drive}\) | Drive | - |
| \(A f\) | Fibre rate | kg/s |
| \(P_i\) | Installed power (electric motor rating) | W |
| \(P_a\) | Mean absorbed power | W |
| \(P_d\) | Drive rating (motor: P_i; turbine: 1.33 P_i) | W |
| \(P_i/A\) | Installed power per tonne cane per hour | J/kg |
Method and standards
Specific power on the fibre rate, as tabulated by Hugot.
Where it is used
- Sizing knife drives.
- Comparing preparation power between mills.
Common mistakes
- Using power per tonne cane with a fibre rate.
- Sizing on the mean instead of the installed figure.
Assumptions and limits
- Specific power from practice; adjust for cane variety and harvesting. It is per tonne of fibre per hour, shown in kWh/t (= kW per t/h); a figure per tonne of cane is about 7 times smaller.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 3
- Tables 3.1–3.2 and pp. 43–45
Questions and answers
Why per tonne of fibre?
The work of cutting depends on the fibre passing, not on the juice; fibre rate compares mills fairly.
How much of the installed power is used?
On average about 60 %; the rest covers peaks when thick layers or tangled cane arrive.
Why more for a turbine?
A motor can take short overloads; a turbine slows down, so its rating is about a third higher.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.