Worked example
Example: 3750 t at 300 kg/m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cane stock | 3,750.0 t |
| Bulk density of the stacked cane | 300.00 kg/m³ |
| Mean stack height | 3.0000 m |
| Share of the yard area that holds cane | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stack volume | 12,500 m³ |
| Area under cane | 4,166.7 m² |
| Gross yard area | 6,944.4 m² |
Open this example in the calculator and change any input.
Formula
\(V = \frac{P}{\rho_b}, \quad A_n = \frac{V}{H}, \quad A_g = \frac{A_n}{u}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Cane stock | kg |
| \(\rho_b\) | Bulk density of the stacked cane | kg/m³ |
| \(H\) | Mean stack height | m |
| \(u\) | Share of the yard area that holds cane | - |
| \(V\) | Stack volume | m³ |
| \(A_n\) | Area under cane | m² |
| \(A_g\) | Gross yard area | m² |
Method and standards
Mass, volume and area for a stack of mean height H.
Where it is used
- Laying out cane yards.
- Checking yard capacity for a crush expansion.
Common mistakes
- Using the density of cane in trucks for loose stacks.
- Taking the peak stack height as the mean height.
Assumptions and limits
- Mean stack height over the whole cane area. A note appears for a bulk density outside Hugot's 200–400 kg/m³.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 1
- bulk densities of cane
- p. 1
Questions and answers
Which bulk density?
It depends on how the cane is loaded: Hugot gives about 200 kg/m³ for grab-loaded whole cane and 300–380 for chopped cane.
Why an allowance for roads?
Cranes, unloaders and vehicles need room; often only half to two-thirds of the yard holds cane.
Does the stack height matter?
Yes: area falls in proportion, but high stacks crush the bottom cane and slow unloading.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.