Worked example
Example: 250 TCH carrier. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Carrier width | 2.1000 m |
| Cane bed height | 1.0000 m |
| Cane bulk density on the carrier | 180.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Carrier speed | 11.023 m/min |
| Cane load per metre of carrier | 378.00 kg/m |
Open this example in the calculator and change any input.
Formula
\(v = \frac{C}{\rho_b W H}, \quad q_L = \rho_b W H = \frac{C}{v}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Crushing rate | kg/s |
| \(W\) | Carrier width | m |
| \(H\) | Cane bed height | m |
| \(\rho_b\) | Cane bulk density on the carrier | kg/m³ |
| \(v\) | Carrier speed | m/s |
| \(q_L\) | Cane load per metre of carrier | kg/m |
Method and standards
Continuity.
Where it is used
- Cane handling design.
- Feed control setting.
Common mistakes
- Prepared-cane density for whole cane.
Assumptions and limits
- Uniform bed.
References
- Continuity v = ṁ/(ρ W H); bulk density by measurement
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (1986)
- ch. 2
- eqns 2.3–2.8 and bulk densities
- pp. 22–26
Questions and answers
Bulk density of cane?
Whole stalk cane on a carrier is roughly 150–250 kg/m³; prepared cane is denser.
Why a steady bed?
Even feeding keeps the mills loaded and extraction steady.
Kicker and leveller?
They set the bed height this calculation assumes.