FireCADCalc

Cane Carrier Power (Hugot)

Slat cane carrier power from the cane load, the chain and slat weight, friction and the lift, by Hugot eqns 2.9–2.13, with his rough and installed rules (2.14–2.15).

Sugar mill and cogenerationElectric motor

Inputs

Examples: 250 TCH carrierSliding slats

Hugot: 18–30 kg/m.
Per metre of carrier length, for the whole width: Hugot gives 32–40 kg per metre length per metre of width, so multiply by the carrier width (75 kg/m is about 2 m wide).
0.30 on rollers; 0.60 if the slats slide.
The empty return run on its rollers or rails; 0.15 is a FireCAD starting value, not a figure from Hugot. Use the carrier maker's value.
Hugot: 1.4–1.5.

Results

Hugot's rules use metric horsepower (75 kgf·m/s) with Z_t in metres and A in t/h.

Cane on the loaded length8.3333t
Weight of chains and slats on one run3.0000t
Friction power9.9537kW
Lifting power2.2882kW
Carrier power12.242kW
Rough estimate (3Z_t + A)/20 hp11.032kW
Installed power, Hugot rule (3Z_t + A)/10 hp22.065kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 TCH carrier. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Carrier speed8.0000 m/min
Loaded length of the carrier40.000 m
Total length of apron (both runs)90.000 m
Height the cane is lifted7.0000 m
Chain mass per metre, each of the two chains25.000 kg/m
Slat mass per metre of carrier length75.000 kg/m
Friction coefficient, loaded run0.30000 -
Friction coefficient, return run0.15000 -
Gearing and drive factor1.4500 -

Applying the formula below gives:

ResultValue
Cane on the loaded length20.833 t
Weight of chains and slats on one run5.6250 t
Friction power16.649 kW
Lifting power6.9123 kW
Carrier power23.561 kW
Rough estimate (3Z_t + A)/20 hp19.123 kW
Installed power, Hugot rule (3Z_t + A)/10 hp38.246 kW

Open this example in the calculator and change any input.

Formula

\(Q = \frac{A\,Z_c}{u}, \quad K = \frac{Z_t}{2}(2p + p')\)

\(P_f = [(Q + K)f + K f']\,g\,u\,\lambda, \quad P_e = A\,g\,H\,\lambda, \quad P = P_f + P_e\)

\(P_r = \frac{3Z_t + A}{20}, \quad P_i = \frac{3Z_t + A}{10} \;[\mathrm{metric\ hp}]\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(u\) Carrier speed m/s
\(Z_c\) Loaded length of the carrier m
\(Z_t\) Total length of apron (both runs) m
\(H\) Height the cane is lifted m
\(p\) Chain mass per metre, each of the two chains kg/m
\(p'\) Slat mass per metre of carrier length kg/m
\(f\) Friction coefficient, loaded run -
\(f'\) Friction coefficient, return run -
\(\lambda\) Gearing and drive factor -
\(Q\) Cane on the loaded length kg
\(K\) Weight of chains and slats on one run kg
\(P_f\) Friction power W
\(P_e\) Lifting power W
\(P\) Carrier power W
\(P_r\) Rough estimate (3Z_t + A)/20 hp W
\(P_i\) Installed power, Hugot rule (3Z_t + A)/10 hp W

Method and standards

Hugot's force balance on the loaded and return runs plus the work of lifting the cane, multiplied by a drive factor.

Where it is used

  • Motor sizing for main and feeder cane carriers.
  • Checking an existing carrier after a crush increase.

Common mistakes

  • Using the chain mass for both chains as p.
  • Taking the speed in m/min in the SI form.

Assumptions and limits

  • Steady load evenly spread on the loaded length.
  • The slat mass is per metre of carrier length for the whole width (Hugot's figure per metre of width times the width). The return-run friction default is a FireCAD starting value.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 2
  • eqns 2.9–2.15
  • pp. 27–29

Questions and answers

Why the factor λ?

It covers gearing losses and the extra effort of starting and of uneven loading; Hugot uses 1.4–1.5.

Which friction for the loaded run?

0.30 when the slats run on rollers, 0.60 when they slide on rails.

What is Z_t?

The total apron length, both runs; each run carries half the chain and slat weight.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.