FireCADCalc

Fixed-Ended Beam: Moments and Deflection

End and mid-span moments, reactions and maximum deflection of a beam fixed at both ends under a central point load or a uniformly distributed load.

Inputs

Examples: 10 kN/m over 4 mCentral 20 kN on 3 m2 kN/m over 6 m, timber 11 GPa

Results

Fully fixed ends are rare in practice; real supports allow some rotation, which moves moment to mid-span.

Moment at the fixed ends (hogging)13,333N·m
Moment at mid-span (sagging)6,666.7N·m
Reaction at each end20.000kN
Deflection at mid-span3.9872mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 kN/m over 4 m. The inputs, in the units selected above:

InputValue
LoadingUniform load w over the span
Central point load0 kN
Uniform load per metre10.000 kN/m
Span4.0000 m
Young's modulus200.00 GPa
Second moment of area836.00 cm⁴

Applying the formula below gives:

ResultValue
Moment at the fixed ends (hogging)13,333 N·m
Moment at mid-span (sagging)6,666.7 N·m
Reaction at each end20.000 kN
Deflection at mid-span3.9872 mm

Open this example in the calculator and change any input.

Formula

\(\text{UDL: } M_e = \frac{wL^2}{12},\ M_c = \frac{wL^2}{24},\ \delta = \frac{wL^4}{384EI}; \quad \text{point: } M_e = M_c = \frac{WL}{8},\ \delta = \frac{WL^3}{192EI}\)

Variables

Symbol Meaning SI unit
\(\text{load}\) Loading -
\(W\) Central point load N
\(w\) Uniform load per metre N/m
\(L\) Span m
\(E\) Young's modulus Pa
\(I\) Second moment of area m⁴
\(M_e\) Moment at the fixed ends (hogging) N·m
\(M_c\) Moment at mid-span (sagging) N·m
\(R\) Reaction at each end N
\(\delta_{max}\) Deflection at mid-span m

Method and standards

Elastic beam theory.

Where it is used

  • Continuous frames and built-in beams.
  • Strength of materials examinations.

Common mistakes

  • Assuming full fixity.
  • Mixing load per metre and total load.

Assumptions and limits

  • Prismatic beam, small deflections.
  • The point load W is used for the central-load case and the load per metre w for the uniform case, each in its own unit.
  • Stresses are not computed (no section modulus input): σ = M/Z with the larger of M_e and M_c. Support rotation, which relieves the end moments, is not modelled.

References

  • Textbook mechanics (standard beam formulas, Roark's Formulas for Stress and Strain)

Questions and answers

10 kN/m over a 4 m fixed beam?

End moments 13.3 kN·m, mid-span 6.7 kN·m, reactions 20 kN.

How does it compare with simply supported?

Deflection is a fifth, and the largest moment two thirds.

Central point load?

WL/8 at the ends and at mid-span; deflection WL³/(192EI).

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.