FireCADCalc

Euler Column Buckling Load and Critical Stress

Critical buckling load and stress of a slender column by Euler's formula for the four classic end conditions, with radius of gyration and slenderness ratio.

Inputs

Examples: Steel, I 100 cm⁴, A 20 cm², 3 m, pinnedAluminium post 2 m, cantileverSteel column 8 m, fixed both ends, I 2 500 cm⁴

With a yield strength, a critical stress at or above it is flagged: the column is not slender and Euler does not apply.

Results

Elastic buckling of a perfectly straight column. If the critical stress is near or above the yield stress the column is not slender: use an inelastic (Johnson) or design-code column curve with a safety factor.

Critical buckling load219.32kN
Critical stress109.66MPa
Least radius of gyration22.361mm
Effective length K L3.0000m
Slenderness ratio134.16

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steel, I 100 cm⁴, A 20 cm², 3 m, pinned. The inputs, in the units selected above:

InputValue
Modulus of elasticity200.00 GPa
Least second moment of area of the section100.00 cm⁴
Cross-section area2,000.0 mm²
Yield strength (0 = not checked)0 MPa
Column length3.0000 m
End condition (effective length factor)Pinned at both ends (K = 1)

Applying the formula below gives:

ResultValue
Critical buckling load219.32 kN
Critical stress109.66 MPa
Least radius of gyration22.361 mm
Effective length K L3.0000 m
Slenderness ratio134.16

Open this example in the calculator and change any input.

Formula

\(P_{cr} = \frac{\pi^2 E I}{(K L)^2}, \quad \sigma_{cr} = \frac{P_{cr}}{A}\)

\(r = \sqrt{I / A}, \quad L_e = K L, \quad \lambda = L_e / r\)

Variables

Symbol Meaning SI unit
\(E\) Modulus of elasticity Pa
\(I\) Least second moment of area of the section m⁴
\(A\) Cross-section area m²
\(\sigma_y\) Yield strength (0 = not checked) Pa
\(L\) Column length m
\(K\) End condition (effective length factor) -
\(P_{cr}\) Critical buckling load N
\(\sigma_{cr}\) Critical stress Pa
\(r\) Least radius of gyration m
\(L_e\) Effective length K L m
\(L_e / r\) Slenderness ratio -

Method and standards

Euler's elastic buckling load for an ideal straight column; the effective length factor K gives the theoretical values for the classic end conditions.

Where it is used

  • Checking struts, props, pump columns and pipe supports.
  • Comparing sections for a column.
  • Teaching and first checks.

Common mistakes

  • Using the larger I instead of the least one.
  • Taking practical end fixity as fully fixed.
  • Using Euler for short columns.

Assumptions and limits

  • Elastic, perfectly straight, centrally loaded column.
  • No safety factor applied.
  • With a yield strength entered, a critical stress at or above it is flagged.
  • Theoretical K values. Design practice uses larger recommended values for imperfect fixity (for example 0.65 fixed–fixed, 0.80 fixed–pinned and 2.1 fixed–free).

References

  • L. Euler (1757); effective length factors (Timoshenko and Gere, Theory of Elastic Stability)

Questions and answers

What load buckles a 3 m pinned steel column with I = 100 cm⁴?

π²EI/L² = 219 kN; on a 20 cm² section that is 110 MPa.

How do the ends change it?

Through the effective length KL: 2 for a cantilever (a quarter of the pinned load), 0.699 fixed–pinned, 0.5 fixed–fixed (four times).

When does Euler not apply?

When the critical stress approaches yield, as in short stocky columns; then a Johnson or design-code column curve governs.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.