Worked example
Example: Process pump 2 950 rpm, 100 m³/h, 80 m, NPSHr 4 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Speed | 2,950.0 rpm |
| Flow at best efficiency, per impeller eye | 100.00 m³/h |
| Head at best efficiency, per stage | 80.000 m |
| NPSH required at best efficiency (first stage) | 4.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific speed nq (rpm, m³/s, m) | 18.380 |
| Specific speed Ns (rpm, US gpm, ft) | 949.26 |
| Suction specific speed Nss (rpm, US gpm, ft) | 8,977.5 |
| Dimensionless specific speed | 0.34733 |
Open this example in the calculator and change any input.
Formula
\(n_q = \frac{n\sqrt{Q}}{H^{3/4}}\ \ (\text{rpm, m}^3/\text{s, m}) \qquad N_s = \frac{n\sqrt{Q}}{H^{3/4}}\ \ (\text{rpm, US gpm, ft})\)
\(N_{ss} = \frac{n\sqrt{Q}}{NPSH_r^{3/4}}\ \ (\text{rpm, US gpm, ft}) \qquad \omega_s = \frac{\omega\sqrt{Q}}{(gH)^{3/4}},\ \ \omega = 2\pi n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | speed | 1/s |
| \(Q\) | flow at best efficiency per impeller eye | m³/s |
| \(H\) | head at best efficiency per stage | m |
| \(NPSH_r\) | NPSH required at best efficiency, first stage | m |
| \(n_q\) | specific speed, metric | – |
| \(N_s\) | specific speed, US units | – |
| \(N_{ss}\) | suction specific speed, US units | – |
| \(\omega_s\) | dimensionless specific speed | – |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Definitions of ANSI/HI 1.3 (specific speed) and ANSI/HI 9.6.1 (suction specific speed). Unit conversions from FireCAD's unit registry (NIST SP 811 factors).
Where it is used
- Choosing pump type (radial, mixed flow, axial).
- Comparing pump designs and efficiencies.
- Checking suction performance.
Common mistakes
- Mixing US and metric specific speed units.
- Using total head of a multistage pump instead of head per stage.
- Using flow of a double-suction pump without halving it.
Assumptions and limits
- At the best efficiency point with the full impeller diameter.
- Per stage for multistage pumps and per impeller eye for double-suction impellers (enter half the flow).
References
- ANSI/HI 1.3 (specific speed)
- ANSI/HI 9.6.1 (suction specific speed)
Questions and answers
What is pump specific speed?
A number that describes the impeller shape for a duty. nq = n·√Q/H^0.75 with n in rpm, Q in m³/s and H in m. A pump at 2 950 rpm, 100 m³/h and 80 m has nq = 18.4 (US Ns = 949), a radial impeller.
Why are there two numbers?
Metric nq uses m³/s and m; US Ns uses US gpm and ft. Ns ≈ 51.6 × nq. The calculator gives both and the dimensionless form, which is the same in any unit system.
What is suction specific speed for?
Nss uses NPSH required in place of head. High values point to an impeller eye designed for low NPSHr, which narrows the stable operating range; ANSI/HI 9.6.1 discusses the limits.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.