FireCADCalc

Pump Specific Speed and Suction Specific Speed

Specific speed nq (metric) and Ns (US), suction specific speed Nss, and the dimensionless value of a centrifugal pump at its best efficiency point.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserHydraulic Institute (pumps)Pump

Inputs

Examples: Process pump 2 950 rpm, 100 m³/h, 80 m, NPSHr 4 mBFW pump stage 2 980 rpm, 65 m³/h, 110 m per stage, NPSHr 6 mCooling water pump 990 rpm, 2 500 m³/h, 25 m, NPSHr 7 m

For a double-suction impeller enter half the pump flow.
For a multistage pump divide the total head by the number of stages.

Results

Specific speed nq (rpm, m³/s, m)73.790
Specific speed Ns (rpm, US gpm, ft)3,810.9
Suction specific speed Nss (rpm, US gpm, ft)9,900.6
Dimensionless specific speed1.3944

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Process pump 2 950 rpm, 100 m³/h, 80 m, NPSHr 4 m. The inputs, in the units selected above:

InputValue
Speed2,950.0 rpm
Flow at best efficiency, per impeller eye100.00 m³/h
Head at best efficiency, per stage80.000 m
NPSH required at best efficiency (first stage)4.0000 m

Applying the formula below gives:

ResultValue
Specific speed nq (rpm, m³/s, m)18.380
Specific speed Ns (rpm, US gpm, ft)949.26
Suction specific speed Nss (rpm, US gpm, ft)8,977.5
Dimensionless specific speed0.34733

Open this example in the calculator and change any input.

Formula

\(n_q = \frac{n\sqrt{Q}}{H^{3/4}}\ \ (\text{rpm, m}^3/\text{s, m}) \qquad N_s = \frac{n\sqrt{Q}}{H^{3/4}}\ \ (\text{rpm, US gpm, ft})\)

\(N_{ss} = \frac{n\sqrt{Q}}{NPSH_r^{3/4}}\ \ (\text{rpm, US gpm, ft}) \qquad \omega_s = \frac{\omega\sqrt{Q}}{(gH)^{3/4}},\ \ \omega = 2\pi n\)

Variables

Symbol Meaning SI unit
\(n\) speed 1/s
\(Q\) flow at best efficiency per impeller eye m³/s
\(H\) head at best efficiency per stage m
\(NPSH_r\) NPSH required at best efficiency, first stage m
\(n_q\) specific speed, metric –
\(N_s\) specific speed, US units –
\(N_{ss}\) suction specific speed, US units –
\(\omega_s\) dimensionless specific speed –
\(g\) standard gravity, 9.806 65 m/s²

Method and standards

Definitions of ANSI/HI 1.3 (specific speed) and ANSI/HI 9.6.1 (suction specific speed). Unit conversions from FireCAD's unit registry (NIST SP 811 factors).

Where it is used

  • Choosing pump type (radial, mixed flow, axial).
  • Comparing pump designs and efficiencies.
  • Checking suction performance.

Common mistakes

  • Mixing US and metric specific speed units.
  • Using total head of a multistage pump instead of head per stage.
  • Using flow of a double-suction pump without halving it.

Assumptions and limits

  • At the best efficiency point with the full impeller diameter.
  • Per stage for multistage pumps and per impeller eye for double-suction impellers (enter half the flow).

References

  • ANSI/HI 1.3 (specific speed)
  • ANSI/HI 9.6.1 (suction specific speed)

Questions and answers

What is pump specific speed?

A number that describes the impeller shape for a duty. nq = n·√Q/H^0.75 with n in rpm, Q in m³/s and H in m. A pump at 2 950 rpm, 100 m³/h and 80 m has nq = 18.4 (US Ns = 949), a radial impeller.

Why are there two numbers?

Metric nq uses m³/s and m; US Ns uses US gpm and ft. Ns ≈ 51.6 × nq. The calculator gives both and the dimensionless form, which is the same in any unit system.

What is suction specific speed for?

Nss uses NPSH required in place of head. High values point to an impeller eye designed for low NPSHr, which narrows the stable operating range; ANSI/HI 9.6.1 discusses the limits.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.