Worked example
Example: 150 m³/h at 40 m, 75 % / 93 %, 6 000 h at 8. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 150.00 m³/h |
| Total head | 40.000 m |
| Liquid density | 998.00 kg/m³ |
| Pump efficiency | 75.000 % |
| Motor (and drive) efficiency | 93.000 % |
| Running hours in a year | 6,000.0 h |
| Electricity price per kWh (your currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic power ρ g Q H | 16.312 kW |
| Electrical input | 23.386 kW |
| Wire-to-water efficiency | 69.750 % |
| Energy in a year | 140,316 kWh |
| Cost in a year | 1,122,528 |
| Energy per volume pumped | 0.15591 kWh/m³ |
Open this example in the calculator and change any input.
Formula
\(P_h = \rho g Q H, \quad P_e = \frac{P_h}{\eta_p \eta_m}, \quad E = P_e\, t\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Flow | m³/s |
| \(H\) | Total head | m |
| \(\rho\) | Liquid density | kg/m³ |
| \(\eta_p\) | Pump efficiency | - |
| \(\eta_m\) | Motor (and drive) efficiency | - |
| \(t\) | Running hours in a year | s |
| \(c\) | Electricity price per kWh (your currency) | - |
| \(P_h\) | Hydraulic power ρ g Q H | W |
| \(P_e\) | Electrical input | W |
| \(\eta_{ww}\) | Wire-to-water efficiency | - |
| \(E\) | Energy in a year | J |
| \(C\) | Cost in a year | - |
| \(e_v\) | Energy per volume pumped | J/m³ |
Method and standards
Energy balance.
Where it is used
- Pump energy audits.
- Comparing pump replacements.
Common mistakes
- Using rated rather than actual duty.
- Forgetting drive losses.
Assumptions and limits
- Steady duty.
References
- P = ρ g Q H / (η_p η_m)
Questions and answers
150 m³/h at 40 m for 6000 h at 8 per kWh?
Hydraulic 16.3 kW, input 23.4 kW, about 1,122,528 a year.
What is wire-to-water efficiency?
Pump × motor × drive efficiency: hydraulic power out per electrical power in.
Why kWh per m³?
It lets you compare pumping systems and track deterioration.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.