FireCADCalc

Pump Efficiency from a Site Test

Pump total head, hydraulic power and pump and overall efficiency from site readings of flow, suction and discharge pressure and motor input power.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserPumpElectric motor

Inputs

Examples: 100 m³/h, 5 bar g / 0.3 bar g, 22 kW input, motor 92 %Boiler feed pump 30 m³/h, 45 / 2 bar g, 70 kW, 94 %Cooling water 1 200 m³/h, 3.2 / suction -0.2 bar g, 160 kW, 95 %

Results

Pump total head464.56m
Hydraulic power35.877kW
Pump shaft power65.800kW
Pump efficiency54.524%
Overall (wire-to-water) efficiency51.253%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 m³/h, 5 bar g / 0.3 bar g, 22 kW input, motor 92 %. The inputs, in the units selected above:

InputValue
Measured flow100.00 m³/h
Discharge pressure5.0000 bar g
Suction pressure0.30000 bar g
Height of the discharge gauge above the suction gauge0.50000 m
Suction pipe inside diameter at the gauge150.00 mm
Discharge pipe inside diameter at the gauge100.00 mm
Liquid density998.00 kg/m³
Motor input power (measured)22.000 kW
Motor efficiency at this load92.000 %

Applying the formula below gives:

ResultValue
Pump total head49.034 m
Hydraulic power13.331 kW
Pump shaft power20.240 kW
Pump efficiency65.863 %
Overall (wire-to-water) efficiency60.594 %

Open this example in the calculator and change any input.

Formula

\(H = \frac{p_d - p_s}{\rho g} + \Delta z + \frac{v_d^2 - v_s^2}{2g}\)

\(P_h = \rho g Q H, \quad P_{sh} = P_{in} \eta_m\)

\(\eta_p = P_h / P_{sh}, \quad \eta_o = P_h / P_{in}\)

Variables

Symbol Meaning SI unit
\(Q\) flow m³/s
\(p_d\) discharge pressure Pa
\(p_s\) suction pressure Pa
\(\Delta z\) height of discharge gauge above suction gauge m
\(D_s\) suction pipe diameter m
\(D_d\) discharge pipe diameter m
\(\rho\) liquid density kg/m³
\(P_{in}\) motor input power W
\(\eta_m\) motor efficiency -
\(v_s\) suction velocity m/s
\(v_d\) discharge velocity m/s
\(g\) standard gravity m/s²
\(H\) total head m
\(P_h\) hydraulic power W
\(P_{sh}\) shaft power W
\(\eta_p\) pump efficiency -
\(\eta_o\) overall efficiency -

Method and standards

Total head is the rise in pressure head plus the gauge height difference and the velocity heads at the gauge points. Hydraulic power over shaft power (motor input times motor efficiency) gives the pump efficiency.

Where it is used

  • Energy audits of pumping systems.
  • Checking pump wear and deciding on overhaul.
  • Verifying commissioning performance.

Common mistakes

  • Gauges at different heights without the Δz correction.
  • Using a clamp-on flow reading without checking its accuracy.
  • Taking the nameplate motor efficiency at part load.

Assumptions and limits

  • Steady flow; incompressible liquid; gauges calibrated.

References

  • Pump total head from gauge readings (pressure, elevation and velocity heads, the definition used in ISO 9906 acceptance tests); hydraulic power ρ g Q H

Questions and answers

How efficient is a pump giving 100 m³/h against 5 bar g discharge and 0.3 bar g suction on 22 kW input?

Head about 49 m; hydraulic power 13.3 kW; with a 92 % motor the pump is about 66 % efficient and the set about 61 %.

Why include velocity heads?

When suction and discharge pipes differ in size, the faster discharge velocity is part of the head the pump adds.

What if the pump efficiency comes out too low?

Compare with the maker's curve at the same flow: wear, recirculation or a wrong operating point are common causes.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.