FireCADCalc

Positive Displacement Pump: Slip, Volumetric and Overall Efficiency

Theoretical flow, slip, volumetric efficiency, hydraulic power and overall and mechanical efficiency of a positive displacement pump from a test.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Gear pump 250 mL/rev, 600 rpmScrew pump 1 L/rev, 1450 rpm

Results

Slip rises with differential pressure and falls with viscosity: compare tests at the same conditions.

Theoretical flow87.000m³/h
Slip7.0000m³/h
Volumetric efficiency91.954%
Hydraulic power13.333kW
Overall efficiency83.333%
Mechanical efficiency90.625%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Gear pump 250 mL/rev, 600 rpm. The inputs, in the units selected above:

InputValue
Displacement per revolution0.25000 L
Speed600.00 rpm
Measured delivery8.5000 m³/h
Differential pressure10.000 bar
Shaft power3.2000 kW

Applying the formula below gives:

ResultValue
Theoretical flow9.0000 m³/h
Slip0.50000 m³/h
Volumetric efficiency94.444 %
Hydraulic power2.3611 kW
Overall efficiency73.785 %
Mechanical efficiency78.125 %

Open this example in the calculator and change any input.

Formula

\(Q_t = V_dN, \quad S = Q_t - Q, \quad \eta_v = \frac{Q}{Q_t}, \quad \eta_o = \frac{Q\Delta p}{P_s}, \quad \eta_m = \frac{\eta_o}{\eta_v}\)

Variables

Symbol Meaning SI unit
\(V_d\) Displacement per revolution m³
\(N\) Speed 1/s
\(Q\) Measured delivery m³/s
\(\Delta p\) Differential pressure Pa
\(P_s\) Shaft power W
\(Q_t\) Theoretical flow m³/s
\(S\) Slip m³/s
\(\eta_v\) Volumetric efficiency -
\(P_h\) Hydraulic power W
\(\eta_o\) Overall efficiency -
\(\eta_m\) Mechanical efficiency -

Method and standards

Definitions.

Where it is used

  • Dosing, fuel oil and molasses pumps.
  • Condition monitoring of gear and screw pumps.

Common mistakes

  • Using nameplate displacement for a worn pump.
  • Measuring flow at a different pressure from the power.

Assumptions and limits

  • Steady test conditions.

References

  • Positive displacement pump definitions (Perry's Chemical Engineers' Handbook, 9th ed. (McGraw-Hill, 2019), sec. 10, positive displacement pumps)

Questions and answers

What is slip?

Liquid leaking back through clearances from discharge to suction; delivery is displacement minus slip.

Why does slip fall with viscosity?

Thicker liquid leaks less through the same clearances; gear pumps on thin liquids show high slip.

What do the defaults give?

250 mL/rev at 600 rpm, 8.5 m³/h at 10 bar on 3.2 kW: 94 % volumetric, 74 % overall.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.