FireCADCalc

Hydraulic Accumulator Size (Boyle's Law)

Gas volume of a bladder or piston accumulator to deliver a volume of oil between a maximum and minimum pressure, for isothermal and adiabatic (fast) operation.

Inputs

Examples: 2 L between 100 and 200 bar, 90 bar pre-charge, adiabatic5 L between 150 and 210 bar, 135 bar, isothermal0.5 L between 40 and 60 bar, 36 bar, 1.3

Results

Absolute pressures are used inside (gauge + 1 atm). A pre-charge about 90 % of the minimum working pressure is common practice; follow the maker.

Accumulator gas volume5.5488L
Gas volume if isothermal (n = 1)4.4620L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 L between 100 and 200 bar, 90 bar pre-charge, adiabatic. The inputs, in the units selected above:

InputValue
Oil volume to deliver2.0000 L
Gas pre-charge pressure (gauge)90.000 bar
Minimum working pressure (gauge)100.00 bar
Maximum working pressure (gauge)200.00 bar
Polytropic exponent (1 isothermal, 1.4 adiabatic nitrogen)1.4000 -

Applying the formula below gives:

ResultValue
Accumulator gas volume5.5488 L
Gas volume if isothermal (n = 1)4.4620 L

Open this example in the calculator and change any input.

Formula

\(V_0 = \frac{\Delta V}{\left(\dfrac{p_0}{p_1}\right)^{1/n} - \left(\dfrac{p_0}{p_2}\right)^{1/n}}\)

Variables

Symbol Meaning SI unit
\(\Delta V\) Oil volume to deliver m³
\(p_0\) Gas pre-charge pressure (gauge) Pa
\(p_1\) Minimum working pressure (gauge) Pa
\(p_2\) Maximum working pressure (gauge) Pa
\(n\) Polytropic exponent (1 isothermal, 1.4 adiabatic nitrogen) -
\(V_0\) Accumulator gas volume m³
\(V_{0,iso}\) Gas volume if isothermal (n = 1) m³

Method and standards

Polytropic gas law between the two pressures.

Where it is used

  • Emergency and pulsation accumulators.
  • Power unit design.

Common mistakes

  • Gauge pressures in the ratio.
  • Pre-charge above minimum pressure.

Assumptions and limits

  • Ideal gas.
  • One exponent n from pre-charge to p₁ and on to p₂. Makers often treat pre-charge and slow filling as isothermal and only a fast discharge as adiabatic; the isothermal result V₀,iso and the adiabatic V₀ bracket that mixed case.

References

  • Boyle's law and polytropic gas compression p Vⁿ = constant

Questions and answers

2 L between 100 and 200 bar with 90 bar pre-charge, fast discharge?

About 5.5 L of gas volume (n = 1.4); 4.5 L if slow (isothermal).

Why absolute pressures?

Boyle's law works on absolute pressure.

Why does speed matter?

Fast cycles do not exchange heat, so the gas behaves adiabatically and delivers less.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.