Worked example
Example: 30 kW unit at 70 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pump input power | 30.000 kW |
| Overall system efficiency (useful work/input) | 70.000 % |
| Reservoir heat-losing area | 3.0000 m² |
| Reservoir coefficient to air | 12.000 W/(m²·K) |
| Allowed oil temperature | 55.000 °C |
| Ambient temperature | 35.000 °C |
| Oil density | 870.00 kg/m³ |
| Oil specific heat | 1.9000 kJ/(kg·K) |
| Oil volume in the system | 400.00 L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat generated | 9.0000 kW |
| Heat lost by the reservoir | 0.72000 kW |
| Cooler duty needed | 8.2800 kW |
| Warm-up rate without cooler | 0.81670 K/min |
Open this example in the calculator and change any input.
Formula
\(Q = P_{in}(1 - \eta), \quad Q_r = UA_r(T_{oil} - T_a), \quad Q_c = \max(Q - Q_r,\ 0), \quad \frac{dT}{dt} = \frac{Q}{V\rho_o c_{p,o}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{in}\) | Pump input power | W |
| \(\eta\) | Overall system efficiency (useful work/input) | - |
| \(A_r\) | Reservoir heat-losing area | m² |
| \(U\) | Reservoir coefficient to air | W/(m²·K) |
| \(T_{oil}\) | Allowed oil temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(\rho_o\) | Oil density | kg/m³ |
| \(c_{p,o}\) | Oil specific heat | J/(kg·K) |
| \(V\) | Oil volume in the system | m³ |
| \(Q\) | Heat generated | W |
| \(Q_r\) | Heat lost by the reservoir | W |
| \(Q_c\) | Cooler duty needed | W |
| \(dT/dt\) | Warm-up rate without cooler, in K/min | K/min |
Method and standards
Energy balance.
Where it is used
- Oil cooler selection.
- Diagnosing overheating systems.
Common mistakes
- Sizing at mild ambient.
- Ignoring relief-valve flow in fixed pumps.
Assumptions and limits
- Steady state; the warm-up rate ignores the heat capacity of the steel and is shown in K/min in every unit system.
References
- Energy balance of a hydraulic system (definitions)
Questions and answers
Where does the heat come from?
Pump and motor losses, throttling in valves and relief flow; a system at 70 % efficiency turns 30 % of its input into heat.
Can the reservoir alone do the cooling?
Only for small or lightly used systems; reservoirs lose roughly 10–15 W/(m²·K).
What do the defaults represent?
A 30 kW power unit at 70 % efficiency with a 3 m² reservoir in 35 °C ambient.