Worked example
Example: 100/40 mm at 100 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet (low) pressure (absolute) | 100.00 bar |
| Large (low-pressure) piston diameter | 100.00 mm |
| Small (high-pressure) piston diameter | 40.000 mm |
| Inlet flow | 30.000 L/min |
| Mechanical efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Area (intensification) ratio | 6.2500 |
| Outlet pressure | 557.81 bar |
| Outlet flow | 4.8000 L/min |
Open this example in the calculator and change any input.
Formula
\(p_2 - p_a = \eta (p_1 - p_a)\frac{A_1}{A_2}, \quad Q_2 = Q_1\frac{A_2}{A_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Inlet (low) pressure (absolute) | Pa |
| \(D_1\) | Large (low-pressure) piston diameter | m |
| \(D_2\) | Small (high-pressure) piston diameter | m |
| \(Q_1\) | Inlet flow | m³/s |
| \(\eta\) | Mechanical efficiency | - |
| \(p_a\) | Atmospheric pressure, 101 325 Pa | Pa |
| \(A_1/A_2\) | Area (intensification) ratio | - |
| \(p_2\) | Outlet pressure | Pa |
| \(Q_2\) | Outlet flow | m³/s |
Method and standards
Force and volume balance.
Where it is used
- Hydraulic clamping and test benches.
- Air-over-oil boosters.
Common mistakes
- Ignoring efficiency at high ratios.
- Forgetting the pressure rating of downstream parts.
Assumptions and limits
- No leakage.
- Pressures absolute; the backs of both pistons are vented to atmosphere (p_a = 101 325 Pa), so the intensification applies to gauge pressure.
References
- Force balance on stepped pistons (definitions)
Questions and answers
How does an intensifier raise pressure?
The same force acts on a smaller area: pressure rises by the area ratio, flow falls by it.
Where are they used?
Clamping, test rigs, presses and water-jet cutting, where a small flow at high pressure is needed from a low-pressure supply.
What do the defaults represent?
A 100 mm/40 mm intensifier fed at 100 bar and 30 L/min.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.