Worked example
Example: 63/20 mm, 200 mm stroke, 6 bar g, 10 per min, double acting. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bore | 63.000 mm |
| Rod diameter | 20.000 mm |
| Stroke | 200.00 mm |
| Supply pressure (gauge) | 6.0000 bar |
| Cycles per minute | 10.000 - |
| Cylinder | Double acting |
Applying the formula below gives:
| Result | Value |
|---|---|
| Free air per cycle | 8.1956 L |
| Free air consumption | 81.956 L/min |
| Theoretical extend force | 1.8703 kN |
Open this example in the calculator and change any input.
Formula
\(V_c = \left[A s + (A - a) s\right]\frac{p + p_{atm}}{p_{atm}}, \quad Q = V_c\, n_c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Bore | m |
| \(d\) | Rod diameter | m |
| \(s\) | Stroke | m |
| \(p\) | Supply pressure (gauge) | Pa |
| \(n_c\) | Cycles per minute | - |
| \(\text{acting}\) | Cylinder | - |
| \(V_c\) | Free air per cycle | m³ |
| \(Q\) | Free air consumption | m³/s |
| \(F\) | Theoretical extend force | N |
Method and standards
Swept volume at supply pressure converted to free air.
Where it is used
- Compressor sizing.
- Air audits.
Common mistakes
- Gauge pressure as compression ratio.
- Forgetting the return stroke.
Assumptions and limits
- Full stroke each cycle.
- Free air is at standard atmospheric pressure (101.325 kPa) and the supply-air temperature (isothermal filling); a FAD or ANR figure quoted at another reference temperature differs slightly.
References
- Swept volume × compression ratio (p + p_atm)/p_atm
Questions and answers
63 mm bore, 20 mm rod, 200 mm stroke, 6 bar g, 10 cycles a minute?
About 8.2 L of free air per cycle, 82 L/min.
Why multiply by the compression ratio?
The cylinder fills with air at supply pressure, which is more free air.
What about hoses?
They are filled and exhausted every cycle too.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.