Worked example
Example: 50 mm rod, 1.5 m, fixed–free, 80 kN. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rod diameter | 50.000 mm |
| Fully extended length (mounting to load) | 1.5000 m |
| Effective length factor | Fixed–free (2.0) |
| Elastic modulus | 207.00 GPa |
| Rod yield strength (0 = Euler only) | 0 MPa |
| Working force | 80.000 kN |
Applying the formula below gives:
| Result | Value |
|---|---|
| Second moment of area | 306,796 mm⁴ |
| Buckling load (Euler; Johnson for a short rod when σ_y is given) | 69.643 kN |
| Safety factor | 0.87054 |
| Slenderness ratio | 240.00 |
Open this example in the calculator and change any input.
Formula
\(P_{cr} = \frac{\pi^2EI}{(KL)^2}, \quad I = \frac{\pi d^4}{64}, \quad SF = \frac{P_{cr}}{F}\) \(P_{cr} = A\sigma_y\left[1 - \frac{\sigma_y}{4\pi^2E}\left(\frac{KL}{r}\right)^2\right]\ \ \text{(Johnson, when}\ \frac{KL}{r} < \sqrt{\frac{2\pi^2E}{\sigma_y}}\text{)}, \quad A = \frac{\pi d^2}{4}, \quad r = \frac d4\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | Rod diameter | m |
| \(L\) | Fully extended length (mounting to load) | m |
| \(K\) | Effective length factor | - |
| \(E\) | Elastic modulus | Pa |
| \(\sigma_y\) | Rod yield strength (0 = Euler only) | Pa |
| \(F\) | Working force | N |
| \(I\) | Second moment of area | m⁴ |
| \(P_{cr}\) | Buckling load (Euler; Johnson for a short rod when σ_y is given) | N |
| \(SF\) | Safety factor | - |
| \(KL/r\) | Slenderness ratio | - |
Method and standards
Euler buckling.
Where it is used
- Long-stroke cylinders.
- Checking a cylinder after a mounting change.
Common mistakes
- Using retracted length.
- Using Euler for short stocky rods.
Assumptions and limits
- Rod only. With no yield strength Euler is used for any slenderness (an overestimate for short rods, flagged below KL/r 100); with σ_y the Johnson parabola applies below the transition slenderness.
- Theoretical K (0.5, 0.7, 1, 2). Design practice often uses larger values for imperfect fixity (for example 0.65 and 0.8 for the fixed–fixed and fixed–pinned cases).
- A safety factor below 1 (buckles) or below 3 is flagged.
References
- Euler column buckling with effective length factors (definitions)
Questions and answers
Which mounting is worst?
A cylinder fixed at one end with the rod end free to swing (K = 2) buckles at a quarter of the pinned–pinned load.
What length to use?
The fully extended distance from the mounting point to the load connection.
What do the defaults represent?
A 50 mm rod, 1.5 m extended, fixed–free, pushing 80 kN.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.