Worked example
Example: 40 cc/rev, 1 450 rpm, 200 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Displacement per revolution | 40.000 mL |
| Speed | 1,450.0 rpm |
| Pressure rise | 200.00 bar |
| Volumetric efficiency | 95.000 % |
| Overall efficiency | 88.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual flow | 55.100 L/min |
| Hydraulic power Q Δp | 18.367 kW |
| Shaft power | 20.871 kW |
| Shaft torque | 137.45 N·m |
Open this example in the calculator and change any input.
Formula
\(Q = V_g\, n\, \eta_v, \quad P_h = Q\, \Delta p, \quad P_s = \frac{P_h}{\eta_t}, \quad T = \frac{P_s}{2\pi n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_g\) | Displacement per revolution | m³ |
| \(n\) | Speed | 1/s |
| \(\Delta p\) | Pressure rise | Pa |
| \(\eta_v\) | Volumetric efficiency | - |
| \(\eta_t\) | Overall efficiency | - |
| \(Q\) | Actual flow | m³/s |
| \(P_h\) | Hydraulic power Q Δp | W |
| \(P_s\) | Shaft power | W |
| \(T\) | Shaft torque | N·m |
Method and standards
Displacement and energy balance.
Where it is used
- Sizing pumps and motors for power packs.
- Checking a power unit.
Common mistakes
- cc/rev as L.
- Ignoring efficiency.
Assumptions and limits
- Steady operation; overall efficiency not above the volumetric efficiency.
References
- Positive-displacement pump relations Q = V_g n η_v; P = Q Δp / η
Questions and answers
40 cc/rev at 1450 rpm and 200 bar?
55.1 L/min, 18.4 kW hydraulic, 20.9 kW at the shaft.
Quick rule?
kW ≈ L/min × bar / 600 hydraulic.
Why two efficiencies?
Leakage lowers flow; friction raises torque.