Worked example
Example: 2 L between 100 and 200 bar, 90 bar pre-charge, adiabatic. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oil volume to deliver | 2.0000 L |
| Gas pre-charge pressure (gauge) | 90.000 bar |
| Minimum working pressure (gauge) | 100.00 bar |
| Maximum working pressure (gauge) | 200.00 bar |
| Polytropic exponent (1 isothermal, 1.4 adiabatic nitrogen) | 1.4000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Accumulator gas volume | 5.5488 L |
| Gas volume if isothermal (n = 1) | 4.4620 L |
Open this example in the calculator and change any input.
Formula
\(V_0 = \frac{\Delta V}{\left(\dfrac{p_0}{p_1}\right)^{1/n} - \left(\dfrac{p_0}{p_2}\right)^{1/n}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\Delta V\) | Oil volume to deliver | m³ |
| \(p_0\) | Gas pre-charge pressure (gauge) | Pa |
| \(p_1\) | Minimum working pressure (gauge) | Pa |
| \(p_2\) | Maximum working pressure (gauge) | Pa |
| \(n\) | Polytropic exponent (1 isothermal, 1.4 adiabatic nitrogen) | - |
| \(V_0\) | Accumulator gas volume | m³ |
| \(V_{0,iso}\) | Gas volume if isothermal (n = 1) | m³ |
Method and standards
Polytropic gas law between the two pressures.
Where it is used
- Emergency and pulsation accumulators.
- Power unit design.
Common mistakes
- Gauge pressures in the ratio.
- Pre-charge above minimum pressure.
Assumptions and limits
- Ideal gas.
- One exponent n from pre-charge to p₁ and on to p₂. Makers often treat pre-charge and slow filling as isothermal and only a fast discharge as adiabatic; the isothermal result V₀,iso and the adiabatic V₀ bracket that mixed case.
References
- Boyle's law and polytropic gas compression p Vⁿ = constant
Questions and answers
2 L between 100 and 200 bar with 90 bar pre-charge, fast discharge?
About 5.5 L of gas volume (n = 1.4); 4.5 L if slow (isothermal).
Why absolute pressures?
Boyle's law works on absolute pressure.
Why does speed matter?
Fast cycles do not exchange heat, so the gas behaves adiabatically and delivers less.