Compressor Free Air Delivery by Pump-Up Test

Actual free air delivery of a compressor on site from the time it takes to pump a receiver of known volume between two pressures, compared with its rating.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserTank and drumAir compressor and receiver

Inputs

Examples: 5 m³, 4 to 7 bar g in 105 s, rated 10 m³/min2 m³, 5 to 7 bar g in 60 s, rated 5 m³/min10 m³, 6 to 8 bar g in 50 s, rated 30 m³/min

Results

Below 80 % of rating: check the inlet filter, valves, belts and leaks inside the package.

Actual free air delivery23.246m³/min
Share of the rated delivery77.485%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 m³, 4 to 7 bar g in 105 s, rated 10 m³/min. The inputs, in the units selected above:

InputValue
Receiver and pipe volume (isolated from users)5.0000 m³
Pressure at the start of the timing4.0000 bar g
Pressure at the end of the timing7.0000 bar g
Time taken105.00 s
Atmospheric pressure (absolute)101.33 kPa
Compressor inlet air temperature30.000 °C
Air temperature in the receiver40.000 °C
Rated free air delivery10.000 m³/min

Applying the formula below gives:

ResultValue
Actual free air delivery8.1892 m³/min
Share of the rated delivery81.892 %

Open this example in the calculator and change any input.

Formula

\(\dot V_a = \frac{V\,(p_2 - p_1)}{p_a\,t}\,\frac{T_a}{T_r} \qquad \frac{\dot V_a}{\dot V_r}\)

Variables

Symbol Meaning SI unit
\(V\) receiver and pipe volume m³
\(p_1\) start pressure Pa
\(p_2\) end pressure Pa
\(t\) time s
\(p_a\) atmospheric pressure Pa
\(T_a\) inlet temperature K
\(T_r\) receiver air temperature K
\(\dot V_r\) rated FAD m³/s
\(\dot V_a\) actual FAD m³/s
\(\dot V_a / \dot V_r\) share of rating –

Method and standards

Mass balance on the receiver with the ideal-gas law; a site check, not the ISO 1217 acceptance test.

Where it is used

  • Checking compressor wear.
  • Verifying a new compressor on site.
  • Energy audits.

Common mistakes

  • Leaving users connected.
  • Ignoring pipe volume.
  • Timing from a cold receiver.

Assumptions and limits

  • Ideal gas; uniform receiver temperature; no leaks.

References

  • Receiver pump-up (filling) method
  • ideal gas

Questions and answers

What FAD does a 5 m³ receiver from 4 to 7 bar g in 105 s show?

8.19 m³/min (inlet 30 °C, receiver 40 °C), 82 % of a 10 m³/min rating.

How do I run the test?

Isolate the receiver and pipework from users, drain it, start the compressor and time the rise between two gauge readings.

Why correct for temperature?

Warm air in the receiver holds fewer kilograms; the correction refers the mass to inlet conditions.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.