FireCADCalc

Compressor Specific Power, Isothermal Efficiency and Air Cost

Specific power, isothermal and adiabatic efficiency and cost per m³ of free air of an air compressor from measured delivery, pressure and input power.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 65 kW, 10 m³/min, 8 bar(a)Old reciprocating, 40 kW, 5 m³/min

1.4 for air; other gases from their data.

Results

Efficiencies are package (wire-to-air) values including motor and drive. Good screw and centrifugal plants at 7 bar(g) run about 6–7 kW per m³/min.

Specific power (kW per m³/min)8.0000
Isothermal power17.447kW
Isothermal efficiency43.618%
Adiabatic efficiency (N stages, equal ratios)50.739%
Cost per m³ of free air1.0667

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 65 kW, 10 m³/min, 8 bar(a). The inputs, in the units selected above:

InputValue
Measured free air delivery (at suction conditions, ISO 1217)10.000 m³/min
Suction pressure (absolute)101.33 kPa
Discharge pressure (absolute)8.0000 bar
Suction temperature30.000 °C
Measured electrical input65.000 kW
Number of compression stages2.0000 -
Ratio of specific heats1.4000 -
Electricity cost per kWh (currency)8.0000 -

Applying the formula below gives:

ResultValue
Specific power (kW per m³/min)6.5000
Isothermal power34.894 kW
Isothermal efficiency53.684 %
Adiabatic efficiency (N stages, equal ratios)62.447 %
Cost per m³ of free air0.86667

Open this example in the calculator and change any input.

Formula

\(SP = \frac{P_{in}}{\dot V_{FAD}}, \quad P_{iso} = p_1\dot V_{FAD}\ln\frac{p_2}{p_1}, \quad P_{ad} = N\frac{\gamma}{\gamma - 1}p_1\dot V_{FAD}\left[\left(\frac{p_2}{p_1}\right)^{\frac{\gamma - 1}{\gamma N}} - 1\right]\)

Variables

Symbol Meaning SI unit
\(\dot V_{FAD}\) Measured free air delivery (at suction conditions, ISO 1217) m³/s
\(\gamma\) Ratio of specific heats -
\(p_1\) Suction pressure (absolute) Pa
\(p_2\) Discharge pressure (absolute) Pa
\(T_1\) Suction temperature K
\(P_{in}\) Measured electrical input W
\(N\) Number of compression stages -
\(c_e\) Electricity cost per kWh (currency) -
\(SP\) Specific power (kW per m³/min) -
\(P_{iso}\) Isothermal power W
\(\eta_{iso}\) Isothermal efficiency -
\(\eta_{ad}\) Adiabatic efficiency (N stages, equal ratios) -
\(c_{air}\) Cost per m³ of free air -

Method and standards

Ideal compression work.

Where it is used

  • Compressed air audits.
  • Comparing compressor offers.

Common mistakes

  • Using rated rather than measured FAD.
  • Comparing at different discharge pressures.

Assumptions and limits

  • Ideal gas; equal stage ratios; a whole number of stages.
  • Free air delivery at the suction pressure and temperature (ISO 1217), so p₁V̇ = ṁRT₁ and the suction temperature cancels out of the ideal powers.

References

  • Ideal isothermal and staged isentropic compression of air (definitions)

Questions and answers

What is a good specific power?

About 6–7 kW per m³/min at 7 bar(g) for modern screw compressors; reciprocating units can be better, old or part-loaded units much worse.

Why isothermal efficiency?

It compares against the least possible work; 60–70 % package values are typical.

What do the defaults represent?

A 65 kW package delivering 10 m³/min at 8 bar(a).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.