Worked example
Example: 65 kW, 10 m³/min, 8 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured free air delivery (at suction conditions, ISO 1217) | 10.000 m³/min |
| Suction pressure (absolute) | 101.33 kPa |
| Discharge pressure (absolute) | 8.0000 bar |
| Suction temperature | 30.000 °C |
| Measured electrical input | 65.000 kW |
| Number of compression stages | 2.0000 - |
| Ratio of specific heats | 1.4000 - |
| Electricity cost per kWh (currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific power (kW per m³/min) | 6.5000 |
| Isothermal power | 34.894 kW |
| Isothermal efficiency | 53.684 % |
| Adiabatic efficiency (N stages, equal ratios) | 62.447 % |
| Cost per m³ of free air | 0.86667 |
Open this example in the calculator and change any input.
Formula
\(SP = \frac{P_{in}}{\dot V_{FAD}}, \quad P_{iso} = p_1\dot V_{FAD}\ln\frac{p_2}{p_1}, \quad P_{ad} = N\frac{\gamma}{\gamma - 1}p_1\dot V_{FAD}\left[\left(\frac{p_2}{p_1}\right)^{\frac{\gamma - 1}{\gamma N}} - 1\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_{FAD}\) | Measured free air delivery (at suction conditions, ISO 1217) | m³/s |
| \(\gamma\) | Ratio of specific heats | - |
| \(p_1\) | Suction pressure (absolute) | Pa |
| \(p_2\) | Discharge pressure (absolute) | Pa |
| \(T_1\) | Suction temperature | K |
| \(P_{in}\) | Measured electrical input | W |
| \(N\) | Number of compression stages | - |
| \(c_e\) | Electricity cost per kWh (currency) | - |
| \(SP\) | Specific power (kW per m³/min) | - |
| \(P_{iso}\) | Isothermal power | W |
| \(\eta_{iso}\) | Isothermal efficiency | - |
| \(\eta_{ad}\) | Adiabatic efficiency (N stages, equal ratios) | - |
| \(c_{air}\) | Cost per m³ of free air | - |
Method and standards
Ideal compression work.
Where it is used
- Compressed air audits.
- Comparing compressor offers.
Common mistakes
- Using rated rather than measured FAD.
- Comparing at different discharge pressures.
Assumptions and limits
- Ideal gas; equal stage ratios; a whole number of stages.
- Free air delivery at the suction pressure and temperature (ISO 1217), so p₁V̇ = ṁRT₁ and the suction temperature cancels out of the ideal powers.
References
- Ideal isothermal and staged isentropic compression of air (definitions)
Questions and answers
What is a good specific power?
About 6–7 kW per m³/min at 7 bar(g) for modern screw compressors; reciprocating units can be better, old or part-loaded units much worse.
Why isothermal efficiency?
It compares against the least possible work; 60–70 % package values are typical.
What do the defaults represent?
A 65 kW package delivering 10 m³/min at 8 bar(a).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.