Worked example
Example: Desiccant dryer, 10 m³/min, 35 °C 70 %, 8 bar(a), 40 °C cooler, −40 °C PDP. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Free air delivery | 10.000 m³/min |
| Intake temperature | 35.000 °C |
| Intake relative humidity | 70.000 % |
| Intake pressure | 101.33 kPa |
| Line pressure (absolute) | 8.0000 bar |
| After-cooler outlet temperature (saturated) | 40.000 °C |
| Dryer pressure dew point | -40.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water entering with the air | 16.622 kg/h |
| Condensed in the after-cooler | 12.794 kg/h |
| Removed by the dryer | 3.8210 kg/h |
| Total condensate per day (as water at 1 kg/L) | 398.76 L |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = \dot m_a(W_0 - W_{sat}(p, T)), \quad W = \frac{M_w}{M_a}\frac{p_v}{p - p_v}\ (\approx 0.622\ldots)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_{FAD}\) | Free air delivery | m³/s |
| \(T_i\) | Intake temperature | K |
| \(\phi\) | Intake relative humidity | - |
| \(p_a\) | Intake pressure | Pa |
| \(p\) | Line pressure (absolute) | Pa |
| \(T_{ac}\) | After-cooler outlet temperature (saturated) | K |
| \(T_{pdp}\) | Dryer pressure dew point (below 0 °C: over ice) | K |
| \(\dot m_{w,in}\) | Water entering with the air | kg/s |
| \(\dot m_{ac}\) | Condensed in the after-cooler | kg/s |
| \(\dot m_{d}\) | Removed by the dryer | kg/s |
| \(\dot m_{day}\) | Total condensate per day, as a volume of water at 1 000 kg/m³ | m³ |
Method and standards
Humid-air mass balance.
Where it is used
- Drain and oil–water separator sizing.
- Dryer selection.
Common mistakes
- Ignoring the after-cooler's share.
- Using atmospheric dew point for pressure dew point.
Assumptions and limits
- Saturated air at the cooler outlet.
- Dew points below 0 °C (desiccant dryers) use saturation over ice (IAPWS R14-08); the water is then held by the desiccant rather than drained.
- The daily total is shown as a volume of water at 1 000 kg/m³.
References
- Humid-air saturation with IAPWS-IF97 (FireCAD engine) and mass balance (definitions)
Questions and answers
Why so much water?
Compression concentrates the intake's moisture; cooling the air back near ambient at 7 bar(g) squeezes most of it out.
Where does the condensate go?
Through drains on the after-cooler, receiver and filters; it often carries compressor oil and needs separation before discharge.
What do the defaults represent?
10 m³/min of humid 35 °C air compressed to 8 bar(a), after-cooled to 40 °C and dried to a 3 °C dew point.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.