Worked example
Example: 8 mm fillet, 50 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Leg length z (not the throat; throat a = 0.707 z) | 8.0000 mm |
| Weld length | 50.000 m |
| Reinforcement allowance (share of the triangle) | 15.000 % |
| Weld metal density | 7,850.0 kg/m³ |
| Deposition efficiency (deposited / consumed) | 60.000 % |
| Mass of one electrode (0 for wire) | 30.000 g |
Applying the formula below gives:
| Result | Value |
|---|---|
| Weld cross-section | 36.800 mm² |
| Weld metal deposited | 14.444 kg |
| Consumables needed | 24.073 kg |
| Electrodes (rounded up) | 803.00 |
Open this example in the calculator and change any input.
Formula
\(A = \frac{z^2}{2}(1 + k_r), \quad m_w = A L \rho, \quad m_c = \frac{m_w}{\eta_d}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(z\) | Leg length z (not the throat; throat a = 0.707 z) | m |
| \(L\) | Weld length | m |
| \(k_r\) | Reinforcement allowance (share of the triangle) | - |
| \(\rho\) | Weld metal density | kg/m³ |
| \(\eta_d\) | Deposition efficiency (deposited / consumed) | - |
| \(m_e\) | Mass of one electrode (0 for wire) | kg |
| \(A\) | Weld cross-section | m² |
| \(m_w\) | Weld metal deposited | kg |
| \(m_c\) | Consumables needed | kg |
| \(N_e\) | Electrodes (rounded up) | - |
Method and standards
Geometry.
Where it is used
- Fabrication estimates.
- Boiler and structural welding.
Common mistakes
- Throat used as leg.
- Ignoring stub loss.
Assumptions and limits
- Equal-leg fillet. Enter the leg length; a throat size a corresponds to a leg of a/0.707 (entering the throat as the leg understates the weld metal by half).
References
- Triangle area z²/2 with reinforcement; consumables = deposit / deposition efficiency
Questions and answers
8 mm fillet, 50 m, 15 % reinforcement?
14.4 kg of weld metal; 24.1 kg of electrodes at 60 %.
Why does leg size matter so much?
Weld metal grows with the square of the leg: a 10 mm fillet has 56 % more than 8 mm.
Unequal legs?
Use the mean of the two legs squared, or the true triangle area.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.