FireCADCalc

Weld Dilution from Cross-Section Areas

Dilution of a weld (share of melted base metal in the weld metal) from the areas of melted base metal and added filler, with the weld content of an element.

Thermal power plantProcess steam and utilities

Inputs

Examples: Stainless filler on carbon steelOverlay 40 % dilution

Results

Measure areas on a macro-etched section. Composition by simple mixing of base and filler.

Dilution40.000%
Element in the weld metal15.080%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Stainless filler on carbon steel. The inputs, in the units selected above:

InputValue
Melted base metal area18.000 mm²
Added filler metal area42.000 mm²
Element in the base metal (mass fraction)0 %
Element in the filler metal19.000 %

Applying the formula below gives:

ResultValue
Dilution30.000 %
Element in the weld metal13.300 %

Open this example in the calculator and change any input.

Formula

\(D = \frac{A_b}{A_b + A_f}, \quad c_w = D c_b + (1 - D)c_f\)

Variables

Symbol Meaning SI unit
\(A_b\) Melted base metal area m²
\(A_f\) Added filler metal area m²
\(c_b\) Element in the base metal (mass fraction) -
\(c_f\) Element in the filler metal -
\(D\) Dilution -
\(c_w\) Element in the weld metal -

Method and standards

Area ratio.

Where it is used

  • Stainless overlays and dissimilar joints.
  • Hardfacing.

Common mistakes

  • Using total weld area as filler.
  • Volume vs mass basis for very different densities.

Assumptions and limits

  • Uniform mixing.
  • Dilution is an area (volume) share, applied here to mass-fraction compositions: this assumes base and filler of similar density (not true for, say, a nickel alloy on aluminium).

References

  • Dilution D = A_base/(A_base + A_filler); weld composition by mixing

Questions and answers

18 mm² base melted, 42 mm² filler, 19 % Cr filler on carbon steel?

Dilution 30 %: about 13.3 % Cr in the weld.

Why does it matter?

Dissimilar and overlay welds can lose the alloy they need.

How to reduce dilution?

Lower heat input, more passes, weaving.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.