FireCADCalc

Electrode Consumption, Arc Time and Welding Time

Electrode or wire mass for a weld metal mass from deposition efficiency, arc time from deposition rate, and total time from operating factor.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 10 kg weld metal by SMAWSAW 200 kg, 8 kg/h

Results

Typical deposition efficiencies: SMAW 55–65 % (stubs, flux, spatter), FCAW 80–85 %, GMAW 90–95 %, SAW about 99 % of wire. Operating factor: manual 20–40 %, semi-automatic 30–50 %, mechanised 50–80 %.

Electrode or wire mass16.667kg
Arc time6.6667h
Total welding time22.222h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 kg weld metal by SMAW. The inputs, in the units selected above:

InputValue
Weld metal required10.000 kg
Deposition efficiency60.000 %
Deposition rate1.5000 kg/h
Operating factor (arc-on time share)30.000 %

Applying the formula below gives:

ResultValue
Electrode or wire mass16.667 kg
Arc time6.6667 h
Total welding time22.222 h

Open this example in the calculator and change any input.

Formula

\(m_e = \frac{m_w}{\eta_d}, \quad t_a = \frac{m_w}{\dot m_d}, \quad t = \frac{t_a}{OF}\)

Variables

Symbol Meaning SI unit
\(m_w\) Weld metal required kg
\(\eta_d\) Deposition efficiency -
\(\dot m_d\) Deposition rate kg/s
\(OF\) Operating factor (arc-on time share) -
\(m_e\) Electrode or wire mass kg
\(t_a\) Arc time s
\(t\) Total welding time s

Method and standards

Mass and time balance.

Where it is used

  • Estimating consumables and labour.
  • Comparing processes.

Common mistakes

  • Using wire deposition efficiency for SMAW.
  • Forgetting the operating factor.

Assumptions and limits

  • Average rates.

References

  • Mass balance with deposition efficiency and operating factor (Lincoln Electric, Procedure Handbook of Arc Welding)

Questions and answers

Why buy more electrode than weld metal?

Stub ends, slag, spatter and fumes take a third or more of an SMAW electrode.

What is operating factor?

The share of the welder's paid time with the arc on; setting up, chipping and moving use the rest.

What do the defaults represent?

10 kg of weld metal by manual metal arc welding.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.