Worked example
Example: Illustrative gas, 30 % O2, flue 1200 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel lower heating value | 50.000 MJ/kg |
| Stoichiometric air per kg fuel | 17.200 kg/kg |
| Oxidant excess ratio | 1.1000 - |
| Flue gas exit temperature | 1,200.0 °C |
| Mean flue gas specific heat | 1.2500 kJ/(kg·K) |
| Reference temperature | 25.000 °C |
| Oxygen in the enriched oxidant (volume) | 30.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Available heat with air | 41.485 % |
| Available heat enriched | 57.785 % |
| Fuel saving | 28.209 % |
| Oxidant per kg fuel (enriched) | 13.371 kg/kg |
Open this example in the calculator and change any input.
Formula
\(AH = 1 - \frac{(1 + m_{ox})c_p(T_f - T_0)}{LHV}, \quad m_{ox} = \frac{\lambda A_{st}w_{O_2,air}}{w_{O_2,ox}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(LHV\) | Fuel lower heating value | J/kg |
| \(A_{st}\) | Stoichiometric air per kg fuel | kg/kg |
| \(\lambda\) | Oxidant excess ratio | - |
| \(T_f\) | Flue gas exit temperature | K |
| \(c_p\) | Mean flue gas specific heat | J/(kg·K) |
| \(T_0\) | Reference temperature | K |
| \(y_{O_2}\) | Oxygen in the enriched oxidant (volume) | - |
| \(AH_{air}\) | Available heat with air | - |
| \(AH_{enr}\) | Available heat enriched | - |
| \(\Delta F/F\) | Fuel saving | - |
| \(m_{ox}\) | Oxidant per kg fuel (enriched) | kg/kg |
Method and standards
Oxygen enrichment.
Where it is used
- Melting and reheating furnaces.
- Comparing enrichment with air preheat.
Common mistakes
- Mixing volume and mass fractions of oxygen.
- Ignoring the cost of oxygen.
Assumptions and limits
- Constant mean flue c_p; complete combustion; same exit temperature.
References
- Available heat with nitrogen ballast
Questions and answers
Why does oxygen save fuel?
Nitrogen in air absorbs heat and leaves with the flue gas; less nitrogen means less heat lost up the stack.
When is it worthwhile?
In high-temperature processes where flue gas leaves above about 1,000 °C and the oxygen is cheap relative to fuel.
What do the defaults represent?
An illustrative natural gas (50 MJ/kg, 17.2 kg/kg air) at 10 % excess oxidant, flue at 1,200 °C, enriched to 30 % oxygen.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)