Worked example
Example: Steel bar 50 mm x 1 m at 900 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Surface temperature | 900.00 °C |
| Ambient temperature | 30.000 °C |
| Emissivity of the surface | 0.75000 - |
| Exposed surface area | 0.15708 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Convection loss density, 1.86ΔT^1.3 | 12.328 kW/m² |
| Convection loss density, 1.54ΔT^1.33 | 12.505 kW/m² |
| Radiation loss density | 80.195 kW/m² |
| Total loss density | 92.700 kW/m² |
| Total surface loss | 14.561 kW |
| Radiation share | 86.510 % |
Open this example in the calculator and change any input.
Formula
\(q_{conv} = 1.86(T_s - T_a)^{1.3}, \quad q_{conv}' = 1.54(T_s - T_a)^{1.33}\ [\text{W/m}^2], \quad q_{rad} = \sigma\varepsilon(T_s^4 - T_a^4)\)
Variables
| Symbol | Meaning | SI unit | |
|---|---|---|---|
| \(T_s\) | Surface temperature | K | |
| \(T_a\) | Ambient temperature | K | |
| \(\varepsilon\) | Emissivity of the surface | - | |
| \(A\) | Exposed surface area | m² | |
| \(q_{conv}\) | Convection loss density, 1.86ΔT1.3 | W/m² | |
| \(q_{conv}'\) | Convection loss density, 1.54ΔT1.33 | W/m² | |
| \(q_{rad}\) | Radiation loss density | W/m² | |
| \(q\) | Total loss density | W/m² | |
| \(P_{loss}\) | Total surface loss | W | |
| \(q_{rad}/q\) | Radiation share | - |
Method and standards
Free convection and grey-body radiation.
Where it is used
- Estimating coil thermal efficiency.
- Deciding on refractory linings and transfer covers.
Common mistakes
- Using polished-metal emissivity for oxidised steel.
- Ignoring forced convection on fast strip lines.
Assumptions and limits
- Free convection; grey surface radiating to large surroundings.
Questions and answers
When does radiation dominate?
Above about 500 °C for steel; at forging temperatures it is ten or more times the convection loss.
Why two convection formulas?
Both are empirical fits from different sources; they agree within a few per cent and give a quick estimate.
What do the defaults represent?
An illustrative case: Steel bar 50 mm x 1 m at 900 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Rudnev, Loveless, Cook and Black, Handbook of Induction Heating (Marcel Dekker, 2003), sec. 3.2.2, eqs. 3.15 to 3.18, Table 3.6 and the slab radiation example