Worked example
Example: Steel billet 75 mm x 200 mm to 1250 C in 60 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Billet diameter | 75.000 mm |
| Billet length | 200.00 mm |
| Density of the metal | 7,850.0 kg/m³ |
| Mean specific heat over the temperature range | 670.00 J/(kg·K) |
| Initial temperature | 20.000 °C |
| Final temperature | 1,250.0 °C |
| Heating time | 60.000 s |
| Coil electrical efficiency | 75.000 % |
| Coil thermal efficiency | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Billet mass | 6.9360 kg |
| Power induced in the workpiece | 95.267 kW |
| Power at the coil terminals | 158.78 kW |
| Production rate | 0.41616 t/h |
| Heat content per tonne | 228.92 kWh/t |
| Overall coil efficiency | 60.000 % |
Open this example in the calculator and change any input.
Formula
\(P_w = mc\frac{T_f - T_{in}}{t}, \quad m = \frac{\pi D^2}{4}l\gamma, \quad P_c = \frac{P_w}{\eta_{el}\eta_{th}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Billet diameter | m |
| \(l\) | Billet length | m |
| \(\gamma\) | Density of the metal | kg/m³ |
| \(c\) | Mean specific heat over the temperature range | J/(kg·K) |
| \(T_{in}\) | Initial temperature | K |
| \(T_f\) | Final temperature | K |
| \(t\) | Heating time | s |
| \(\eta_{el}\) | Coil electrical efficiency | - |
| \(\eta_{th}\) | Coil thermal efficiency | - |
| \(m\) | Billet mass | kg |
| \(P_w\) | Power induced in the workpiece | W |
| \(P_c\) | Power at the coil terminals | W |
| \(\dot m\) | Production rate | kg/s |
| \(HC\) | Heat content per tonne | J/kg |
| \(\eta\) | Overall coil efficiency | - |
Method and standards
Energy balance on the workpiece.
Where it is used
- Sizing induction billet and bar heaters.
- Checking a heater's rating against production.
Common mistakes
- Using room-temperature specific heat for steel.
- Taking workpiece power as coil power.
Assumptions and limits
- Uniform through-heating; mean properties.
Questions and answers
Why is coil power so much higher for copper?
Copper's low resistivity makes the workpiece absorb little of the field, so the coil's own I²R loss is comparable with the power delivered: η_el is only 0.35–0.45.
Is this enough for design?
It is a ballpark figure for uniform through-heating; surface hardening or non-uniform start temperatures need numerical simulation.
What do the defaults represent?
An illustrative case: Steel billet 75 mm x 200 mm to 1250 C in 60 s. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Rudnev, Loveless, Cook and Black, Handbook of Induction Heating (Marcel Dekker, 2003), sec. 3.3.1, eqs. 3.19 to 3.23 and the copper billet example