FireCADCalc

Induction Bar Heating Line: Heat Time, Coil Length and Frequency

Ballpark minimum heat time, coil line length, lowest efficient frequency and power for through-heating steel bars to forging temperature by induction.

Inputs

Examples: 50 mm bar, 2 t/h, to 1250 C100 mm billet, 6 t/h, to 1200 C25 mm bar, 0.5 t/h, D/delta 5

Accepted: 5 to 500 mm
Accepted: 3.6 to 180,000 kg/h
Accepted: 0.01 to 10 Ω·mm²/m
Accepted: 1 to 2,000
Accepted: 2 to 20
Accepted: 100 to 2,000 J/(kg·K)
Accepted: -73.15 to 1,726.8 °C
Accepted: 26.85 to 1,726.8 °C
Accepted: 5 to 100 %

Results

Ballpark formulas for carbon steel bars heated from ambient to forging temperature: heat time 25D² s and coil length 0.03 in per lb/h. Eddy currents do not cancel when D/δ exceeds about 4, so the frequency should not fall below f_min; much higher frequencies overheat the surface and lengthen the soak.

Minimum heat time24.219s
Minimum coil line length0.83996m
Lowest frequency for the D/δ ratio11.652kHz
Reference depth at that frequency5.0000mm
Power into the steel105.15kW
Power at the coil terminals175.25kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 mm bar, 2 t/h, to 1250 C. The inputs, in the units selected above:

InputValue
Bar diameter50.000 mm
Production rate2,000.0 kg/h
Resistivity of the hot steel (above the Curie point)1.2000 Ω·mm²/m
Relative permeability (1 above the Curie point)1.0000 -
Required ratio of diameter to reference depth4.0000 -
Mean specific heat, ambient to final670.00 J/(kg·K)
Initial temperature20.000 °C
Final temperature1,250.0 °C
Overall coil efficiency65.000 %

Applying the formula below gives:

ResultValue
Minimum heat time96.875 s
Minimum coil line length3.3598 m
Lowest frequency for the D/δ ratio1.9454 kHz
Reference depth at that frequency12.500 mm
Power into the steel457.83 kW
Power at the coil terminals704.36 kW

Open this example in the calculator and change any input.

Formula

\(t_{min} = 25D^2\ [\text{s, in}], \quad l_{min} = 0.03\,\dot m\ [\text{in, lb/h}], \quad f_{min} = \frac{\rho}{\pi\mu_0\mu_r(D/k)^2}, \quad P_w = \dot mc(T_f - T_{in})\)

Variables

Symbol Meaning SI unit
\(D\) Bar diameter m
\(\dot m\) Production rate kg/s
\(\rho\) Resistivity of the hot steel (above the Curie point) Ω·m
\(\mu_r\) Relative permeability (1 above the Curie point) -
\(D/\delta\) Required ratio of diameter to reference depth -
\(c\) Mean specific heat, ambient to final J/(kg·K)
\(T_{in}\) Initial temperature K
\(T_f\) Final temperature K
\(\eta\) Overall coil efficiency -
\(t_{min}\) Minimum heat time s
\(l_{min}\) Minimum coil line length m
\(f_{min}\) Lowest frequency for the D/δ ratio 1/s
\(\delta\) Reference depth at that frequency m
\(P_w\) Power into the steel W
\(P_c\) Power at the coil terminals W

Method and standards

The ballpark relations for inline bar heating.

Where it is used

  • Preliminary design of forging heaters.
  • Checking an existing line against a new bar size.

Common mistakes

  • Using a frequency set for a larger bar.
  • Taking the coil length as the heated length only.

Assumptions and limits

  • Carbon steel; ambient to forging temperature; continuous feed.

Questions and answers

Why does the heat time grow with D²?

Heat must conduct from the induced surface layer to the centre; conduction time scales with the square of the distance.

Why choose the lowest efficient frequency?

Lower frequency puts the heat deeper and shortens the soak, but below D/δ ≈ 4 the currents cancel and efficiency collapses.

What do the defaults represent?

50 mm carbon steel bar at 2 t/h heated from 20 to 1,250 °C, resistivity 1.2 μΩ·m above the Curie point, mean specific heat 670 J/(kg·K), overall coil efficiency 65 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Rudnev, Loveless, Cook and Black, Handbook of Induction Heating (Marcel Dekker, 2003), sec. 7.1, eqs. 7.1 and 7.2 (ballpark heat time and coil length) and the D/δ > 4 rule; sec. 3.3.1 (power)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.