Results

An FFT of N samples at f_s resolves frequencies Δf = f_s/N apart and needs a record T = N/f_s long: fine resolution needs long records. Analysers show about N/2.56 lines, keeping clear of the anti-aliasing filter's roll-off below the Nyquist frequency f_s/2. A window reduces leakage but widens each bin's noise bandwidth by its ENBW factor (Hann 1.5, flat top 3.77); use the ENBW when converting a spectrum to power spectral density.

Frequency resolution (bin width)0.78125Hz
Record length1,280.0ms
Nyquist frequency25,600Hz
Usable lines (N/2.56)25,600
Equivalent noise bandwidth2.9453Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 25.6 kHz, 4096 samples, Hann. The inputs, in the units selected above:

InputValue
Sampling rate25.600 kHz
Block size (samples)4,096.0 -
WindowHann (1.50)

Applying the formula below gives:

ResultValue
Frequency resolution (bin width)6.2500 Hz
Record length160.00 ms
Nyquist frequency12,800 Hz
Usable lines (N/2.56)1,600.0
Equivalent noise bandwidth9.3750 Hz

Open this example in the calculator and change any input.

Formula

\(\Delta f = \frac{f_s}{N}, \quad T = \frac{N}{f_s}, \quad f_N = \frac{f_s}2, \quad ENBW = k_w\,\Delta f\)

Variables

Symbol Meaning SI unit
\(f_s\) Sampling rate 1/s
\(N\) Block size (samples) -
\(\text{window}\) Window -
\(\Delta f\) Frequency resolution (bin width) 1/s
\(T\) Record length s
\(f_N\) Nyquist frequency 1/s
\(n_L\) Usable lines (N/2.56) -
\(ENBW\) Equivalent noise bandwidth 1/s

Method and standards

FFT resolution.

Where it is used

  • Setting up vibration and acoustic analysers.
  • Separating close frequencies such as motor slip sidebands.

Common mistakes

  • Expecting resolution from a higher sampling rate alone.
  • Using the bin width instead of ENBW for noise levels.

Assumptions and limits

  • Single block; no zero padding.

References

  • Discrete Fourier transform resolution and window noise bandwidth

Questions and answers

How do I get 1 Hz resolution?

Use a record of 1 s: for example 25.6 kHz sampling and 25,600 samples, or 2.56 kHz and 2,560.

Why 2.56?

Analysers sample at 2.56 times the maximum frequency so the anti-aliasing filter can roll off before the Nyquist frequency.

What do the defaults represent?

An illustrative vibration analyser sampling at 25.6 kHz with 4,096-sample blocks and a Hann window.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Oppenheim and Schafer, Discrete-Time Signal Processing, 3rd ed. (Pearson, 2010), Harris, On the use of windows for harmonic analysis with the discrete Fourier transform, Proc. IEEE 66 (1978)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.