FireCADCalc

Rotameter (Variable Area) Density Correction

Corrected flow of a rotameter used on a fluid of different density from its calibration fluid, for liquids and gases, from the float density.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water-calibrated, oil 850, stainless floatAir-calibrated (1.205), nitrogen at 1.165Water-calibrated, brine 1 200, aluminium float

Results

Viscosity effects are ignored; for gases use the density at the meter's actual pressure and temperature.

Volume flow correction factor0.85749
Actual volume flow25.725
Mass flow ratio factor (k ρ₂/ρ₁)1.0290

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water-calibrated, oil 850, stainless float. The inputs, in the units selected above:

InputValue
Scale reading (in the calibration fluid)100.00 -
Float density8,000.0 kg/m³
Density of the calibration fluid1,000.0 kg/m³
Density of the actual fluid850.00 kg/m³

Applying the formula below gives:

ResultValue
Volume flow correction factor1.0962
Actual volume flow109.62
Mass flow ratio factor (k ρ₂/ρ₁)0.93178

Open this example in the calculator and change any input.

Formula

\(k = \sqrt{\frac{\rho_1 (\rho_f - \rho_2)}{\rho_2 (\rho_f - \rho_1)}}, \quad Q_v = k\, Q_s\)

Variables

Symbol Meaning SI unit
\(Q_s\) Scale reading (in the calibration fluid) -
\(\rho_f\) Float density kg/m³
\(\rho_1\) Density of the calibration fluid kg/m³
\(\rho_2\) Density of the actual fluid kg/m³
\(k\) Volume flow correction factor -
\(Q_v\) Actual volume flow -
\(Q_m\) Mass flow ratio factor (k ρ₂/ρ₁) -

Method and standards

Drag on the float balances its submerged weight.

Where it is used

  • Purge and sample flows.
  • Reusing a meter on another fluid.

Common mistakes

  • Gas density at standard instead of meter conditions.
  • Ignoring viscosity for oils.

Assumptions and limits

  • Same viscosity regime.

References

  • Force balance on the float of a variable-area meter (ISO 11605 principle)

Questions and answers

What does a water-calibrated rotameter read for an 850 kg/m³ oil?

Volume flow = scale × 1.0962 with a stainless float.

Why does float density matter?

The float hangs where drag balances its weight less buoyancy.

And for gases?

The float density is far above the gas density, so k ≈ √(ρ₁/ρ₂).

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.