FireCADCalc

Stack Gas Velocity and Flow by Pitot Tube

Flue gas velocity and flow in a stack or duct from a pitot tube's velocity pressure, pitot coefficient and gas temperature, pressure and molar mass, also at normal conditions.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserStack and chimneyFan and blower

Inputs

Examples: S-type pitot 250 Pa, Cp 0.84, 140 °C, 99.5 kPa, M 29.5, stack 2.5 mStandard pitot 120 Pa, Cp 0.99, 180 °C, 100 kPa, M 30, 1.2 mS-type 400 Pa, 0.84, 120 °C, 99 kPa, M 29, 3.5 m

From the pitot's calibration; S-type tubes are about 0.84, standard (Prandtl) tubes about 0.99.

Results

Average the square roots of the velocity pressures over a traverse, not the pressures themselves; a single point does not give the mean velocity.

Gas velocity17.188m/s
Actual volume flow69,980m³/h
Flow at normal conditions (wet)41,631Nm³/h
Gas density in the stack0.79624kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: S-type pitot 250 Pa, Cp 0.84, 140 °C, 99.5 kPa, M 29.5, stack 2.5 m. The inputs, in the units selected above:

InputValue
Average velocity pressure (pitot reading)250.00 Pa
Pitot tube coefficient0.84000 -
Gas temperature140.00 °C
Gas pressure in the stack (absolute)0.99500 bar
Molar mass of the wet gas29.500 kg/kmol
Stack inside diameter2.5000 m

Applying the formula below gives:

ResultValue
Gas velocity20.319 m/s
Actual volume flow359,075 m³/h
Flow at normal conditions (wet)233,123 Nm³/h
Gas density in the stack0.85448 kg/m³

Open this example in the calculator and change any input.

Formula

\(\rho = \frac{p\,M}{R\,T} \qquad v = C_p\sqrt{\frac{2\,\Delta p}{\rho}} \qquad \dot V = v\,\frac{\pi D^2}{4} \qquad \dot V_n = \dot V\,\frac{p}{p_n}\,\frac{T_n}{T}\)

Variables

Symbol Meaning SI unit
\(\Delta p\) velocity pressure Pa
\(C_p\) pitot coefficient –
\(T\) gas temperature K
\(p\) gas pressure Pa
\(M\) molar mass of the wet gas kg/kmol
\(D\) stack diameter m
\(v\) velocity m/s
\(\dot V\) actual flow m³/s
\(\dot V_n\) flow at normal conditions Nm³/s
\(\rho\) gas density kg/m³
\(R\) universal gas constant J/(kmol·K)
\(p_n, T_n\) 101 325 Pa and 273.15 K Pa, K

Method and standards

Pitot-tube equation with ideal-gas density, the principle behind US EPA Method 2; flow at normal conditions by the ideal-gas law.

Where it is used

  • Stack emission testing.
  • Checking fan and ID fan flows.
  • Calibrating continuous flow monitors.

Common mistakes

  • Single-point readings instead of a traverse.
  • Using dry molar mass for wet gas.
  • Ignoring cyclonic flow in the stack.

Assumptions and limits

  • Ideal gas; uniform flow across each traverse point.
  • The normal flow is on a wet basis; for emission reporting convert to dry gas (multiply by 1 − the water vapour fraction) and to the reference O₂ separately.

References

  • Pitot-tube velocity equation
  • the principle of US EPA Method 2

Questions and answers

How fast does the stack gas move?

A velocity pressure of 250 Pa on an S-type pitot (Cp 0.84) in gas at 140 °C, 99.5 kPa and molar mass 29.5 gives 20.3 m/s; in a 2.5 m stack that is 99.7 m³/s, 64.8 Nm³/s.

Why average the square roots?

Velocity goes with the square root of the velocity pressure; averaging the pressures first overstates the mean velocity.

Which coefficient?

The calibrated value of your pitot; S-type tubes are about 0.84, standard (Prandtl) tubes about 0.99.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.