Orifice and Flow Element Permanent Pressure Loss

Permanent pressure loss of an orifice plate from its diameter ratio and DP (ISO 5167-2 approximation), with the pumping power and yearly energy it costs.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserISO 5167 (differential-pressure flow)

Inputs

Examples: β 0.6, 250 mbar, 100 m³/h, 70 %, 8 000 hβ 0.4, 500 mbar, 20 m³/hβ 0.75, 100 mbar, 400 m³/h

Results

The energy assumes the full-flow loss for all running hours, so it is an upper bound: at part flow the loss falls with the square of the flow.

ISO 5167-2 gives 1 − β^1.9 as an approximation for orifice plates; venturi tubes lose only about 5 to 20 % of their DP.

Loss as a share of the DP 1 − β^1.962.113%
Permanent pressure loss155.28mbar
Pumping power for the loss0.61620kW
Energy in a year4,929.6kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: β 0.6, 250 mbar, 100 m³/h, 70 %, 8 000 h. The inputs, in the units selected above:

InputValue
Diameter ratio d/D0.60000 -
Differential pressure at full flow250.00 mbar
Volume flow (for the pumping power)100.00 m³/h
Pump efficiency (for the power)70.000 %
Running hours in a year8,000.0 h

Applying the formula below gives:

ResultValue
Loss as a share of the DP 1 − β^1.962.113 %
Permanent pressure loss155.28 mbar
Pumping power for the loss0.61620 kW
Energy in a year4,929.6 kWh

Open this example in the calculator and change any input.

Formula

\(\frac{\Delta\omega}{\Delta p} \approx 1 - \beta^{1.9}, \quad P = \frac{Q\, \Delta\omega}{\eta}\)

Variables

Symbol Meaning SI unit
\(\beta\) Diameter ratio d/D -
\(\Delta p\) Differential pressure at full flow Pa
\(Q\) Volume flow (for the pumping power) m³/s
\(\eta\) Pump efficiency (for the power) -
\(t\) Running hours in a year s
\(\Delta\omega/\Delta p\) Loss as a share of the DP 1 − β^1.9 -
\(\Delta\omega\) Permanent pressure loss Pa
\(P\) Pumping power for the loss W
\(E\) Energy in a year J

Method and standards

ISO 5167-2 approximation.

Where it is used

  • Choosing flow elements.
  • Energy audits of metering runs.

Common mistakes

  • Treating DP as the loss.
  • Ignoring the element in pump head.

Assumptions and limits

  • Sharp-edged orifice.
  • Annual energy at the full-flow loss for every running hour: an upper bound when the flow varies (the loss falls with flow squared).

References

  • ISO 5167-2:2003 clause on pressure loss (approximation 1 − β^1.9)

Questions and answers

What does a β 0.6 orifice lose at 250 mbar DP?

62 % of the DP: 155 mbar.

What does that cost at 100 m³/h?

0.62 kW of pumping, about 4930 kWh a year.

Why choose a larger β?

Less permanent loss, but a smaller DP for the same flow.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.