Worked example
Example: β 0.6, 250 mbar, 100 m³/h, 70 %, 8 000 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Diameter ratio d/D | 0.60000 - |
| Differential pressure at full flow | 250.00 mbar |
| Volume flow (for the pumping power) | 100.00 m³/h |
| Pump efficiency (for the power) | 70.000 % |
| Running hours in a year | 8,000.0 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Loss as a share of the DP 1 − β^1.9 | 62.113 % |
| Permanent pressure loss | 155.28 mbar |
| Pumping power for the loss | 0.61620 kW |
| Energy in a year | 4,929.6 kWh |
Open this example in the calculator and change any input.
Formula
\(\frac{\Delta\omega}{\Delta p} \approx 1 - \beta^{1.9}, \quad P = \frac{Q\, \Delta\omega}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\beta\) | Diameter ratio d/D | - |
| \(\Delta p\) | Differential pressure at full flow | Pa |
| \(Q\) | Volume flow (for the pumping power) | m³/s |
| \(\eta\) | Pump efficiency (for the power) | - |
| \(t\) | Running hours in a year | s |
| \(\Delta\omega/\Delta p\) | Loss as a share of the DP 1 − β^1.9 | - |
| \(\Delta\omega\) | Permanent pressure loss | Pa |
| \(P\) | Pumping power for the loss | W |
| \(E\) | Energy in a year | J |
Method and standards
ISO 5167-2 approximation.
Where it is used
- Choosing flow elements.
- Energy audits of metering runs.
Common mistakes
- Treating DP as the loss.
- Ignoring the element in pump head.
Assumptions and limits
- Sharp-edged orifice.
- Annual energy at the full-flow loss for every running hour: an upper bound when the flow varies (the loss falls with flow squared).
References
- ISO 5167-2:2003 clause on pressure loss (approximation 1 − β^1.9)
Questions and answers
What does a β 0.6 orifice lose at 250 mbar DP?
62 % of the DP: 155 mbar.
What does that cost at 100 m³/h?
0.62 kW of pumping, about 4930 kWh a year.
Why choose a larger β?
Less permanent loss, but a smaller DP for the same flow.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.