Stack Opacity, Optical Density and Path-Length Correction

Optical density from measured opacity, opacity corrected to the stack exit path length, the extinction coefficient and an estimated dust concentration.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 15 % across 3.2 m to 2.5 m exitCoal boiler 25 % opacityLow opacity bag filter stack

Accepted: 0 to 99 %
Accepted: 0.1 to 20 m
Accepted: 0.1 to 20 m
Accepted: 0.01 to 50 m²/g

Results

Bouguer: D = −log₁₀(1 − Op) is proportional to path length, so D₂ = D₁L₂/L₁ converts opacity to the stack exit, where regulations usually define it. Dust concentration c = b/K_e needs K_e from gravimetric tests at the same plant: it depends strongly on particle size and colour.

Optical density at measurement0.12494
Opacity at stack exit21.467%
Extinction coefficient0.0575361/m
Estimated dust concentration19.179mg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 15 % across 3.2 m to 2.5 m exit. The inputs, in the units selected above:

InputValue
Measured opacity15.000 %
Measurement path length3.2000 m
Stack exit path length2.5000 m
Specific extinction coefficient2.5000 m²/g

Applying the formula below gives:

ResultValue
Optical density at measurement0.070581
Opacity at stack exit11.924 %
Extinction coefficient0.050787 1/m
Estimated dust concentration20.315 mg/m³

Open this example in the calculator and change any input.

Formula

\(D = -\log_{10}(1 - Op), \quad D_2 = D_1\frac{L_2}{L_1}, \quad b = \frac{2.303D_1}{L_1}, \quad c = \frac{b}{K_e}\)

Variables

Symbol Meaning SI unit
\(Op_1\) Measured opacity -
\(L_1\) Measurement path length m
\(L_2\) Stack exit path length m
\(K_e\) Specific extinction coefficient m²/kg
\(D_1\) Optical density at measurement -
\(Op_2\) Opacity at stack exit -
\(b\) Extinction coefficient 1/m
\(c\) Estimated dust concentration kg/m³

Method and standards

Opacity.

Where it is used

  • Continuous opacity monitoring at boiler stacks.
  • Checking ESP and bag filter performance.

Common mistakes

  • Comparing opacities measured over different paths.
  • Using a K_e from another plant.

Assumptions and limits

  • Uniform particle cloud across the path; single scattering.

References

  • Bouguer attenuation for transmissometers

Questions and answers

Why correct opacity to the stack exit?

Opacity depends on how far light travels through the smoke; limits refer to the plume diameter at the exit.

Can an opacity monitor measure dust in mg/m³?

Only with a site calibration against gravimetric samples; the relation changes with particle size and fuel.

What do the defaults represent?

An illustrative 15 % opacity measured across a 3.2 m duct, corrected to a 2.5 m exit, with K_e = 2.5 m²/g.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Lipták, Instrument Engineers' Handbook, Vol. 1: Process Measurement and Analysis, 4th ed. (CRC, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.