FireCADCalc

Thermal Resistance (R-Value) and U-Value Converter

Convert thermal resistance between m²·K/W, h·m²·°C/kcal and h·ft²·°F/Btu (imperial R-value), with the matching U-value in W/(m²·K) and Btu/(h·ft²·°F).

Inputs

Examples: RSI 2Imperial R-19

Results

m²·K/W3.3461m²·K/W
h·m²·°C/kcal3.8915h·m²·°C/kcal
h·ft²·°F/Btu (imperial R-value)19.000h·ft²·°F/Btu
U-value 1/R0.29886W/(m²·K)
U-value, Btu/(h·ft²·°F)0.052632Btu/(h·ft²·°F)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: RSI 2. The inputs, in the units selected above:

InputValue
Thermal resistance (choose its unit)2.0000 m²·K/W

Applying the formula below gives:

ResultValue
m²·K/W2.0000 m²·K/W
h·m²·°C/kcal2.3260 h·m²·°C/kcal
h·ft²·°F/Btu (imperial R-value)11.357 h·ft²·°F/Btu
U-value 1/R0.50000 W/(m²·K)
U-value, Btu/(h·ft²·°F)0.088055 Btu/(h·ft²·°F)

Open this example in the calculator and change any input.

Formula

\(U = \frac{1}{R}\)

Variables

Symbol Meaning SI unit
\(R\) Thermal resistance (choose its unit) m²·K/W
\(U\) U-value 1/R W/(m²·K)

Method and standards

Definitions.

Where it is used

  • Insulation specifications.
  • Cold store panels.

Common mistakes

  • Imperial R used as RSI.
  • Adding U-values instead of R-values.

Assumptions and limits

  • Steady one-dimensional flow.

References

  • U = 1/R; unit definitions per NIST SP 811

Questions and answers

RSI 2.0?

About R-11.4 imperial.

Why 5.68?

One imperial R unit is 0.1761 m²·K/W.

U from R?

U = 1/R for the same element.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.