Salt-Gradient Solar Pond Efficiency and Heat Output

Collection efficiency and useful heat of a salt-gradient solar pond from transmission to the storage zone, loss coefficient and storage and air temperatures.

Food, dairy and textile

Inputs

Examples: Illustrative 3000 m2, 70 C storageHot 85 C, desert sunCool climate 50 C

Accepted: 0.05 to 0.4 kW/m²
Accepted: 5 to 80 %
Accepted: 0.1 to 5 W/(m²·K)
Accepted: 6.85 to 99.85 °C
Accepted: -13.15 to 46.85 °C
Accepted: 10 to 10,000,000 m²

Results

η = τ − U(T_s − T_a)/Ḡ; the gradient layer acts as transparent insulation. Ponds store heat seasonally and deliver 60–90 °C; annual efficiencies of 15–25 % are typical.

Collection efficiency19.000%
Useful heat28.500kW
Useful heat per year249.83MWh
Stagnation temperature (no extraction)97.500°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3000 m2, 70 C storage. The inputs, in the units selected above:

InputValue
Mean solar irradiance on the pond0.23000 kW/m²
Fraction of light reaching the storage zone40.000 %
Overall heat loss coefficient of the storage zone0.80000 W/(m²·K)
Storage zone temperature70.000 °C
Ambient (surface) temperature20.000 °C
Pond area3,000.0 m²

Applying the formula below gives:

ResultValue
Collection efficiency22.609 %
Useful heat156.00 kW
Useful heat per year1,367.5 MWh
Stagnation temperature (no extraction)135.00 °C

Open this example in the calculator and change any input.

Formula

\(\eta = \tau - \frac{U(T_s - T_a)}{\bar G}, \quad T_{stag} = T_a + \frac{\tau\bar G}{U}\)

Variables

Symbol Meaning SI unit
\(\bar G\) Mean solar irradiance on the pond W/m²
\(\tau\) Fraction of light reaching the storage zone -
\(U\) Overall heat loss coefficient of the storage zone W/(m²·K)
\(T_s\) Storage zone temperature K
\(T_a\) Ambient (surface) temperature K
\(A\) Pond area m²
\(\eta\) Collection efficiency -
\(\dot Q\) Useful heat W
\(Q_a\) Useful heat per year J
\(T_{stag}\) Stagnation temperature (no extraction) K

Method and standards

Solar pond balance.

Where it is used

  • Process heat and desalination screening.
  • Teaching solar thermal storage.

Common mistakes

  • Using peak instead of annual mean irradiance.
  • Ignoring ground losses in U.

Assumptions and limits

  • Steady annual average; well-maintained gradient.

References

  • Solar pond collection efficiency

Questions and answers

How does a solar pond trap heat?

Salt makes the bottom water denser even when it is hot, so it does not rise and lose heat; the gradient layer above acts as insulation.

What can the heat be used for?

Low-temperature process heat, desalination, space heating and small organic Rankine cycles.

What do the defaults represent?

An illustrative 3,000 m² pond with 230 W/m² mean sun, 40 % reaching the storage zone, U = 0.8 W/(m²·K), storage at 70 °C and air at 20 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 6, Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.