Partly Shaded Solar Collector: Gain with Series Flow Through Two Zones

Useful gain of a collector with a shaded and an unshaded zone in series, for flow from the low- to high-irradiance zone or the reverse direction.

Inputs

Examples: Illustrative: 30 % shaded at 180 W/m2, rest at 950 W/m2, 0.010 kg/(m2 s), 45 C inletUnshaded collector (zone 1 empty)

Accepted: 0 to 100 %
Accepted: 0 to 1,400 W/m²
Accepted: 0 to 1,400 W/m²
Accepted: 30 to 100 %
Accepted: 30 to 100 %
Accepted: 30 to 100 %
Accepted: 0.5 to 20 W/(m²·K)
Accepted: 0.36 to 360 kg/(m²·h)
Accepted: 1 to 5 kJ/(kg·K)
Accepted: -23.15 to 126.85 °C
Accepted: -43.15 to 56.85 °C

Results

The two zones share F_R and U_L; the second zone sees the warmer outlet of the first. The difference between flow directions is usually small, and an area-average radiation gives nearly the same answer.

Zone coupling factor A_2F_RU_L/(ṁc_p)0.083532
Useful gain per unit area, flow as entered426.01W/m²
Useful gain per unit area with the flow reversed410.00W/m²
Gain using the area-average radiation425.46W/m²
Temperature leaving zone 144.844°C
Collector outlet temperature55.167°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 30 % shaded at 180 W/m2, rest at 950 W/m2, 0.010 kg/(m2 s), 45 C inlet. The inputs, in the units selected above:

InputValue
Share of area in zone 1 (entered first by the flow)30.000 %
Radiation on zone 1180.00 W/m²
Radiation on zone 2950.00 W/m²
Transmittance–absorptance product, zone 175.000 %
Transmittance–absorptance product, zone 285.000 %
Heat removal factor95.000 %
Heat removal factor times loss coefficient5.0000 W/(m²·K)
Flow per unit collector area36.000 kg/(m²·h)
Fluid specific heat4.1900 kJ/(kg·K)
Inlet temperature45.000 °C
Ambient temperature15.000 °C

Applying the formula below gives:

ResultValue
Zone coupling factor A_2F_RU_L/(ṁc_p)0.083532
Useful gain per unit area, flow as entered426.01 W/m²
Useful gain per unit area with the flow reversed410.00 W/m²
Gain using the area-average radiation425.46 W/m²
Temperature leaving zone 144.844 °C
Collector outlet temperature55.167 °C

Open this example in the calculator and change any input.

Formula

\(Q_u = A_1F_R(\tau\alpha)_1(1 - K)G_{T,1} + A_2F_R(\tau\alpha)_2G_{T,2} - F_RU_L[A_1(1 - K) + A_2](T_i - T_a)\)

\(K = \frac{A_2F_RU_L}{\dot mc_p}\)

Variables

Symbol Meaning SI unit
\(A_1/A\) Share of area in zone 1 (entered first by the flow) -
\(G_{T,1}\) Radiation on zone 1 W/m²
\(G_{T,2}\) Radiation on zone 2 W/m²
\((\tau\alpha)_1\) Transmittance–absorptance product, zone 1 -
\((\tau\alpha)_2\) Transmittance–absorptance product, zone 2 -
\(F_R\) Heat removal factor -
\(F_RU_L\) Heat removal factor times loss coefficient W/(m²·K)
\(\dot m/A\) Flow per unit collector area kg/(m²·s)
\(c_p\) Fluid specific heat J/(kg·K)
\(T_i\) Inlet temperature K
\(T_a\) Ambient temperature K
\(K\) Zone coupling factor A_2F_RU_L/(ṁc_p) -
\(Q_u/A\) Useful gain per unit area, flow as entered W/m²
\(Q_u/A\ (reversed)\) Useful gain per unit area with the flow reversed W/m²
\(Q_u/A\ (average)\) Gain using the area-average radiation W/m²
\(T_{o,1}\) Temperature leaving zone 1 K
\(T_o\) Collector outlet temperature K

Method and standards

Series zones of one collector at different irradiance.

Where it is used

  • Arrays with row-to-row shading.
  • Collectors with planar reflectors.

Common mistakes

  • Using the inlet temperature for both zones.
  • Ignoring the shaded zone's lower (τα) for diffuse radiation.

Assumptions and limits

  • Same F_R and U_L for both zones; steady state.

References

  • Hottel–Whillier gain of two collector zones in series

Questions and answers

Does flow direction matter?

A little: sending the flow through the brightly lit zone last usually gains a few per cent, because the low-irradiance zone then works at the colder inlet.

Can I just average the radiation?

Usually yes; the average-radiation estimate is shown for comparison.

What do the defaults represent?

An illustrative row-shaded collector: 30 % of the area in shade at 180 W/m² and the rest at 950 W/m², F_R 0.95, F_RU_L 5.0 W/(m²·K), 0.010 kg/(m²·s) of water at 45 °C with 15 °C ambient.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 10.6, eqs. 10.6.1 to 10.6.5 and Example 10.6.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.