Worked example
Example: Same trough at the stated inlet 155.2 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Aperture width | 2.5000 m |
| Collector length | 10.000 m |
| Glass envelope outer diameter (shades the aperture) | 90.000 mm |
| Absorbed radiation per unit aperture area | 0.43000 kW/m² |
| Absorber outside diameter | 60.000 mm |
| Absorber inside diameter | 50.000 mm |
| Absorber tube conductivity | 16.000 W/(m·K) |
| Inside coefficient | 300.00 W/(m²·K) |
| Receiver loss coefficient (on receiver area) | 3.8200 W/(m²·K) |
| Fluid flow | 0.053700 kg/s |
| Fluid specific heat | 3.2600 kJ/(kg·K) |
| Fluid inlet temperature | 155.20 °C |
| Ambient temperature | 10.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Receiver area | 1.8850 m² |
| Unshaded aperture area | 24.100 m² |
| Concentration ratio A_a/A_r | 12.785 |
| Collector efficiency factor | 98.368 % |
| Flow factor | 98.004 % |
| Heat removal factor | 96.405 % |
| Useful gain | 8.9825 kW |
| Outlet temperature | 206.51 °C |
Open this example in the calculator and change any input.
Formula
\(F' = \frac{1/U_L}{\frac{1}{U_L} + \frac{D_o}{h_{fi}D_i} + \frac{D_o}{2k}\ln\frac{D_o}{D_i}}, \quad F_R = \frac{\dot mc_p}{A_rU_L}\left[1 - \exp\left(-\frac{A_rU_LF'}{\dot mc_p}\right)\right]\)
\(Q_u = F_RA_a\left[S - \frac{A_r}{A_a}U_L(T_i - T_a)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W_a\) | Aperture width | m |
| \(L\) | Collector length | m |
| \(D_g\) | Glass envelope outer diameter (shades the aperture) | m |
| \(S\) | Absorbed radiation per unit aperture area | W/m² |
| \(D_o\) | Absorber outside diameter | m |
| \(D_i\) | Absorber inside diameter | m |
| \(k\) | Absorber tube conductivity | W/(m·K) |
| \(h_{fi}\) | Inside coefficient | W/(m²·K) |
| \(U_L\) | Receiver loss coefficient (on receiver area) | W/(m²·K) |
| \(\dot m\) | Fluid flow | kg/s |
| \(c_p\) | Fluid specific heat | J/(kg·K) |
| \(T_i\) | Fluid inlet temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(A_r\) | Receiver area | m² |
| \(A_a\) | Unshaded aperture area | m² |
| \(C\) | Concentration ratio A_a/A_r | - |
| \(F'\) | Collector efficiency factor | - |
| \(F''\) | Flow factor | - |
| \(F_R\) | Heat removal factor | - |
| \(Q_u\) | Useful gain | W |
| \(T_o\) | Outlet temperature | K |
Method and standards
Hottel–Whillier analysis applied to a concentrating collector.
Where it is used
- Parabolic trough loop performance.
- Industrial process heat collectors.
Common mistakes
- Using aperture area for losses.
- Using DNI instead of absorbed radiation S.
Assumptions and limits
- Steady state; uniform flux around the receiver assumed in F'.
Questions and answers
Why are losses written per receiver area?
Heat is lost only from the small receiver; concentration C = A_a/A_r cuts the loss per unit aperture, which is why concentrators reach high temperatures.
Why is the glass envelope subtracted from the aperture?
It shades the central strip of the mirror from the beam.
What do the defaults represent?
An illustrative case: Same trough at the stated inlet 155.2 C. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 7.3, eqs. 7.3.9 to 7.3.12 and Example 7.3.2