FireCADCalc

Plume Rise and Effective Stack Height (Briggs)

Buoyancy flux of a hot stack plume, distance to final rise, Briggs final plume rise for neutral and unstable air, and the effective stack height.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paper

Inputs

Examples: 60 m boiler stack, 150 °C, 4 m/s windSmall DG stack 30 m, 400 °C, 0.5 m

Results

Briggs buoyant rise for neutral and unstable air (classes A–D), with x_f = 49F^(5/8) (F < 55) or 119F^(2/5). Stable air (classes E–F) gives a lower rise that this does not compute.

Buoyancy flux (m⁴/s³)65.181
Distance to final rise632.70m
Final plume rise118.64m
Effective stack height178.64m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 m boiler stack, 150 °C, 4 m/s wind. The inputs, in the units selected above:

InputValue
Physical stack height60.000 m
Stack exit diameter2.5000 m
Exit velocity15.000 m/s
Exit gas temperature150.00 °C
Ambient temperature30.000 °C
Wind speed at stack top4.0000 m/s

Applying the formula below gives:

ResultValue
Buoyancy flux (m⁴/s³)65.181
Distance to final rise632.70 m
Final plume rise118.64 m
Effective stack height178.64 m

Open this example in the calculator and change any input.

Formula

\(F_b = gv_sd^2\frac{T_s - T_a}{4T_s}, \quad \Delta h = \frac{1.6F_b^{1/3}x_f^{2/3}}{u}\)

Variables

Symbol Meaning SI unit
\(h_s\) Physical stack height m
\(d\) Stack exit diameter m
\(v_s\) Exit velocity m/s
\(T_s\) Exit gas temperature K
\(T_a\) Ambient temperature K
\(u\) Wind speed at stack top m/s
\(F_b\) Buoyancy flux (m⁴/s³) -
\(x_f\) Distance to final rise m
\(\Delta h\) Final plume rise m
\(H\) Effective stack height m

Method and standards

Briggs buoyant rise.

Where it is used

  • Stack design and dispersion screening.
  • Effect of flue gas temperature on dispersion.

Common mistakes

  • Using stable-air conditions with this form.
  • Ignoring downwash.

Assumptions and limits

  • Buoyancy-dominated plume; neutral or unstable air. Stable air gives a lower rise, not computed here.
  • A temperature excess below the Briggs crossover ΔT_c (momentum-dominated plume) and stack-tip downwash (v_s < 1.5u) are flagged.

References

  • Briggs (1975) plume rise equations as used in US EPA dispersion models (de Nevers, Air Pollution Control Engineering, 2nd ed. (McGraw-Hill, 2000), ch. 6)

Questions and answers

Why does plume rise matter?

Ground-level concentration falls roughly with the square of effective height; rise often adds as much as the stack itself.

Why does wind lower the rise?

Stronger wind bends the plume over faster, so it rises less before levelling off.

What do the defaults represent?

A 60 m boiler stack, 2.5 m diameter, 15 m/s at 150 °C in a 4 m/s wind.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators