FireCADCalc

RMS, Average, Form Factor and Crest Factor of Waveforms

RMS value, average (rectified) value, form factor and crest factor of sine, half-wave and full-wave rectified, square and triangular waveforms from the peak.

Inputs

Examples: Sine, 325.27 V peakHalf-wave rectified, 100 V peakFull-wave rectified, 100 V peakSquare wave, 5 VTriangular, 10 V peak

Results

RMS value50.000
Average value (of the rectified wave)31.831
Form factor (RMS / average)1.5708
Crest factor (peak / RMS)2.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sine, 325.27 V peak. The inputs, in the units selected above:

InputValue
WaveformSine wave
Peak value (volts or amperes)325.27 -

Applying the formula below gives:

ResultValue
RMS value230.00
Average value (of the rectified wave)207.07
Form factor (RMS / average)1.1107
Crest factor (peak / RMS)1.4142

Open this example in the calculator and change any input.

Formula

\(V_{rms} = \sqrt{\frac{1}{T}\int_0^T v^2\, dt}, \quad V_{avg} = \frac{1}{T}\int_0^T |v|\, dt\)

\(k_f = \frac{V_{rms}}{V_{avg}}, \quad k_c = \frac{V_p}{V_{rms}}\)

Variables

Symbol Meaning SI unit
\(\text{wave}\) Waveform -
\(V_p\) Peak value (volts or amperes) -
\(V_{rms}\) RMS value -
\(V_{avg}\) Average value (of the rectified wave) -
\(k_f\) Form factor (RMS / average) -
\(k_c\) Crest factor (peak / RMS) -

Method and standards

Closed-form integrals of each waveform over one period.

Where it is used

  • Rectifier and meter work.
  • Electrical examinations.

Common mistakes

  • Using 0.707 for non-sine waves.
  • Confusing average with RMS.

Assumptions and limits

  • Ideal waveforms, no DC offset.

References

  • Definitions of RMS and mean values (integrals over one period)

Questions and answers

What is the RMS of a 325 V peak sine wave?

230 V; form factor 1.11 and crest factor 1.414.

And of a half-wave rectified sine?

RMS V_p/2, average V_p/π, form factor 1.57.

Why does form factor matter?

Average-responding meters assume 1.11 and misread other shapes.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.