FireCADCalc

Star-Delta (Y-Δ) Resistance Conversion

Converts three resistances (or impedances of equal phase angle) between delta (Δ) and star (Y, wye) connection, both ways, by the Kennelly transformation.

Electrician and wireman licence examinations

Inputs

Examples: Delta 30, 60, 90 Ω to starStar 10, 10, 10 Ω to deltaStar 5, 10, 20 Ω to delta

Results

First result: R_a (star) or R_ab (delta)17.500Ω
Second result: R_b (star) or R_bc (delta)70.000Ω
Third result: R_c (star) or R_ca (delta)35.000Ω

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Delta 30, 60, 90 Ω to star. The inputs, in the units selected above:

InputValue
ConversionDelta to star (R_ab, R_bc, R_ca → R_a, R_b, R_c)
First resistance: R_ab (delta) or R_a (star)30.000 Ω
Second resistance: R_bc (delta) or R_b (star)60.000 Ω
Third resistance: R_ca (delta) or R_c (star)90.000 Ω

Applying the formula below gives:

ResultValue
First result: R_a (star) or R_ab (delta)15.000 Ω
Second result: R_b (star) or R_bc (delta)10.000 Ω
Third result: R_c (star) or R_ca (delta)30.000 Ω

Open this example in the calculator and change any input.

Formula

\(R_a = \frac{R_{ab} R_{ca}}{R_{ab} + R_{bc} + R_{ca}}, \quad R_b = \frac{R_{ab} R_{bc}}{\Sigma}, \quad R_c = \frac{R_{bc} R_{ca}}{\Sigma}\)

\(R_{ab} = \frac{R_a R_b + R_b R_c + R_c R_a}{R_c}, \quad R_{bc} = \frac{\cdots}{R_a}, \quad R_{ca} = \frac{\cdots}{R_b}\)

Variables

Symbol Meaning SI unit
\(\text{direction}\) Conversion -
\(R_1\) First resistance: R_ab (delta) or R_a (star) Ω
\(R_2\) Second resistance: R_bc (delta) or R_b (star) Ω
\(R_3\) Third resistance: R_ca (delta) or R_c (star) Ω
\(R'_1\) First result: R_a (star) or R_ab (delta) Ω
\(R'_2\) Second result: R_b (star) or R_bc (delta) Ω
\(R'_3\) Third result: R_c (star) or R_ca (delta) Ω
\(R_{ab}, R_{bc}, R_{ca}\) Delta resistances between terminals Ω
\(R_a, R_b, R_c\) Star resistances from each terminal to the star point Ω
\(\Sigma\) Sum of the delta resistances Ω

Method and standards

Kennelly's transformation makes a delta and a star of resistances look the same between each pair of terminals. Here R₁, R₂, R₃ are R_ab, R_bc, R_ca for a delta or R_a, R_b, R_c for a star, and the results follow the same order.

Where it is used

  • Reducing bridge networks that are neither series nor parallel.
  • Converting three-phase loads to per-phase star values.
  • Earth grid and filter calculations.

Common mistakes

  • Mixing up which star arm sits opposite which delta side.
  • Using magnitudes for impedances of different phase angles.
  • Forgetting a balanced delta is three times the star.

Assumptions and limits

  • Linear passive elements.
  • Magnitudes only: exact for resistances, and for impedances only when all three have the same phase angle. Mixed R, L and C elements need the complex form.

References

  • A.E. Kennelly (1899)
  • star–delta transformation

Questions and answers

What star is equal to a delta of 30, 60 and 90 Ω?

R_a = 15 Ω, R_b = 10 Ω and R_c = 30 Ω: each star arm is the product of the two adjacent delta sides over their sum.

What delta is equal to a star of three 10 Ω?

Three 30 Ω: a balanced delta is three times the balanced star.

Does it work for impedances?

Yes with complex numbers; this page uses magnitudes, which is exact only when all three have the same phase angle.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.